Amroad XL COMMUNITY STATION Manual de instalación - Página 10
Navegue en línea o descargue pdf Manual de instalación para Sistema de interfono Amroad XL COMMUNITY STATION. Amroad XL COMMUNITY STATION 16 páginas.
IO Application
Electric Bolt
IO Application
Electric Bolt
The Electric Bolt is closed when +12 V is
supplied.
The Electric Bolt is opened when +12V is
not supplied.
DI2:Trigger Default is High (LowHigh).
When the Open Button is pressed, the door
will be opened.
DI1:Trigger Default is HighLow,
MS(Magnetic Switch). Magnetic Switch is
detecting door status.
When the electronic circuit connected with the
Electric Bolt completely, you should choose
"Positive" in the item Device Relay Output on
the WEB UI in Entrance Setting – GPIO, and
saved.
Please follow Technical Manual to set WEB UI.
7
AMROAD XL