User Manual – AS5x61/AS5x62 Programming
b. Move magnet assembly to initial position and click "Get". This will take the value
related to the magnet current physical location as the Cordic register initial position.
6) Enter final angle, T2. Two methods are possible, except that this position is the final
position of the magnet's rotation.
a. Manually enter a final position value into "T2 Cordic" field or "T2 (°)", or
b. Move magnet assembly to final position and click "Get". This will take the value
related to the magnet current physical location as the Cordic register initial position.
7)
8) Enter
9) Enter
10) Enter
11) Enter
12) Choose the desired quadrant mode
to 4 quadrants @ 1 revolution.
There are some limits for this programming: 4 Quadrants: max. 90° for each Quadrant
13) Choose the Breakpoint setting: a) Opt is the optimal Breakpoint, calculated by the DLL.
14) Additional Settings:
www.ams.com
This is duty cycle at the initial magnet position.
This is duty cycle at the final magnet position.
Clamping Level Low is the duty cycle at the lower guard band.
Clamping Level High is the voltage at the upper guard band.
3 Quadrants: max 120° for each Quadrant
2 Quadrants: max 180° for each Quadrant
1 Quadrant: full 360°
b) BP : set the BP in the BPW field
c) BP_T1: BP setting related to T1 position. Set value into
BPWT1D field
d) BP_T2: BP setting related to T2 position. Set value into
BPWT2D field
HystLevel: Only used with 1Q 0 – 360° to move the BP.
Direction: Set the right direction for the Application, CCW or CW.
Revision 1.0 / 10/31/12
there are a possibility to programm up
page 9/14