9. Anti mask
The DT12EAM has a sophisticate anti mask module:
This module is assembled on the DT12EAM main board.
To activate the AM please pull up SW2 position 2 .
The DT12EAM has aambient light sensor.
The DT12EAM made self calibration for the anti mask 30 minutes after power up.
Please be verify during installation that the DT12EAM is closed well before 30 minutes
from power up.
If the first power up is under direct sunlight the DT12EAM will made the self calibration 30
minutes after the sun light intensity will decrease
10
Operation
Note! Connect the DT12EAM to a positive Voltage output of 9.6 -16VDC
Use only a listed power limited source.
The detector shall be provided with minimum of 4 hours of standby power from either a
listed compatible control unit or power supply.
The detector is automatically operated once connected to power.
The LEDs start flashing one at a time (side to side) for 30 seconds during the warm-up
period and after that it will turn off.
At this time the detector is ready for operation.