Note: Make sure the scanner is configured so that it does not pull pin 7 low. If the scanner pulls pin 7 low
for any reason, the controller will not configure itself for a scanner. The input is retested on every
power up.
Note: The scanner should be setup so that its ground matches the AMS ground, and its TX goes to the
AMS RX. No other connections are necessary for scanner communication.
Zebra LI3608 Bar Code Scanner Setup
Note: The following setup procedure works only with the Zebra LI3608 bar code scanner. For other bar
code scanners, please contact the manufacturer for proper setup procedures.
When a Zebra LI3608 bar code scanner is connected to an XL200 series controller for the first time, the
scanner must be setup to properly communicate with the controller before it can be used for data entry.
Setup Procedure
1. Turn on the scanner. The scanner plays a musical tone, indicating it is on.
2. Verify that the Power Light on the Power Supply is on.
3. Turn off the XL200 series controller, but leave the scanner turned on.
4. Scan the bar code below. Do not proceed to the next bar code until you hear a beep confirming
the scanner has read the bar code.
5. Once the bar codes are read, the setup is complete and the scanner is ready for operation.
6. Turn the XL200 Series Controller on.
NOTE: This particular scanner does not have the capability of turning off the "RTS/CTS" (pin 7 and
Pin 8) signal as described on page 1 of this document, therefore, pin 7 and Pin 8 of the DB9
Connector MUST be clipped or removed for proper operation of the scanner. See the
troubleshooting section for more details.