Electrolux 727027 Manual de instrucciones de instalación y funcionamiento - Página 17

Navegue en línea o descargue pdf Manual de instrucciones de instalación y funcionamiento para Frigorífico Electrolux 727027. Electrolux 727027 19 páginas. "roll-in smart" electronic control

Electrolux 727027 Manual de instrucciones de instalación y funcionamiento
· Type "E" service alarms
E1
E2
Sensor is broken or disconnected
E3
E4
Sensor is broken or disconnected
E5
E6
Sensor is broken or disconnected
E7
E8
Sensor is broken or disconnected
E9
Low chamber temperature
E10
Low evaporator temperature
C.1.7.5 ALARM MANAGING
· Whenever a high chamber temperature alarm occurs the
display shows the label "TEMP" and the buzzer is active.
· To reset the buzzer press the
second.
· Whenever a type "b" service alarm occurs the display shows
the label code of the alarm and the buzzer is active.
· Whenever a type "E" service alarm occurs the display shows
the label code of the alarm and the buzzer is active. IT IS
NECESSARY TO CONTACT THE TECHNICAL ASSISTANCE.
· To reset the buzzer press the
second.
C.1.7.6 HACCP ALARM RESET
The maximum number of high chamber temperature recording
alarms is 99.
Whenever the memory is full and a "b2" alarm occurs or at the
end of the year, it is necessary to reset the memory in the
following way:
HACCP
· press the
appear;
Sensor short-circuited
Sensor short-circuited
Sensor short-circuited
Sensor short-circuited
HACCP
button for 1
button for 1
button until the label "HiSt" will
· keep pressed together
until the display shows "RES".
C.1.7.7 TROUBLESHOOTING GUIDE
(problems which can be solved immediately)
LABEL
PROBLEM
The door is open
or
b1
m icroswitch
is broken
HACCP
mem ory
b2
is
full
High
temperature
b3
of
condens er
Power
b4
failure
17
RES
SET
HACCP
ACTION
Check the door,
if it's ok,
contact technical
assistance center
Reset HACCP mem ory
Check the condenser,
if it's cleaned or uncovered,
contact technical
ass istance center
Check the power s upply,
if it's ok,
contact technical
ass istance center