4.11.1 Hose system
Several hoses run underneath dishwasher bases: internal drain
hose, condensation tube and water inlet hose. The internal drain
hose connects to the sump and the other hoses connect to the
water inlet / condensation system.
1. Inlet hose
2. Condensation tube
3. Internal drain hose
4. Condensation tube exit
The condensation tube attaches to the base – don't connect it to
a drain.
702_58300000130262_ara_en_c
1
4
2
3
4.12
Sump parts
The sump contains a filter screen, coarse filter and micro filter.
2
1. Coarse filter
2. Microfilter
3. Filter screen
The sump holds the drain pump cover and suction cap. The
suction cap provides a proper flow rate of water through the
sump.
1. Suction cap
2. Drain pump cover
2
1
3
1
2
Page 17 of 50