Drainsafe DS 360M Hoja de instalación

Navegue en línea o descargue pdf Hoja de instalación para Equipos de iluminación Drainsafe DS 360M. Drainsafe DS 360M 2 páginas. Anti-entrapment type, submerged suction outlet type cover

Install Sheet: Drainsafe
Install Sheet: Drainsafe
Anti-Entrapment Type, Submerged Suction Outlet Type Cover
Anti-Entrapment Type, Submerged Suction Outlet Type Cover
This product must be installed by an experienced pool/spa professional.
Read these instructions in their entirety prior to starting installation.
ANSI/APSP – 16 2011 Standard, ANSI/ASME A112.19.8 (2007) and VGB 2008 Compliant.
Safe Flow Rate 123 (GPM) Gallons Per Minute. For use with suction outlet sumps up to 8 inch in size.
Note: It is recommended this product be used in conjunction with a
ANSI/ASME A112.19.17 Certified (SVRS) Safety Vacuum Release System.
Do not exceed Drainsafe
Post safe flow rate in an obvious location in pump room.
Acceptable connecting pipe sizes: up to 2.5".
Inspect this unit for proper attachment daily, inspect for fractured or damaged parts daily.
Never operate any pool/spa facility if drain cover is damaged, cracked, fractured, loose or missing.
Use supplied 316 Grade S/S (12 per kit) security screws to install this anti-entrapment type drain
cover.
Ensure existing sump screw attachment holes are clean and free of debris prior to attachment.
Carefully tighten screws to secure cover. Do not over tighten screws. Damage to the Drainsafe
360M could result, causing serious injury or death.
If the Drainsafe
properly reinstalled.
After slowly tightening supplied screws, be certain Drainsafe
or vertically/horizontally to ensure secure attachment.
► Attempt this operation in a dry environment.
► Do not install this product on seating or backrest of seating area.
► Do not place this product within three feet on the same suction line or mounting plane.
► If one suction outlet should become blocked, the remaining suction outlet(s) shall be capable of handling the
flow of the system.
► Be certain pool/spa pump(s) are secured prior to installation.
► Use battery operated drill (if need be), or a Yankee type manual ratcheted screw driver to predrill holes.
► Use supplied security tool and S/S 316 grade security screws.
► Do not increase flow through system by increasing pump size or horsepower.
► Do not allow children to sit, play or interact with main drains or suction outlets.
Optional tools: Awl, 1/16 inch drill bit, battery operated drill or a "Yankee type" manual ratcheted
screw driver to predrill holes, brush and or dust pan to clean surface area prior to installation.
1. Remove existing main drain cover. Clean area and prep for Drainsafe
2. Install this product in a right side up position. (ANSI/APSP – 16 2011 Standard) labeling is on the top of the unit.
®
Set Drainsafe
DS 360M on sump and align existing screw holes with Drainsafe
7.5 inch bolt centers) this configuration fits most common sump screw patterns. Outer edges must be flush
with existing pool/spa liner. Do not start pump if the edges of the Drainsafe
to the existing liner be it; plaster, exposed aggregate, fiberglass, coated surface or vinyl.
3. Insert the two supplied screws into the existing holes in the sump, (6 sets of screws included to match original
OEM screws) hand tighten. (Do not over tighten!)
4. Then using a 1/16 inch drill bit, drill (2) 1/4 inch deep holes, at a 90 degree off-set (screw holes pre-drilled in
®
Drainsafe
DS 360M) into the existing mud ring plastic, as close to the sumps frame as possible.
5. Use all four (4) screw ports to mount Drainsafe
hand tighten only using the supplied Uni-screw security tool.
®
6. Do not install Drainsafe
(supplied). It is important all four screw attachment openings are utilized. In some cases it may require you pre-
drill four new screw ports for a secure fit.
Keep this document with other important pool/spa papers.

Important Information:

®
DS 360M Safe Flow Rate: 123 gallons per minute.
®
DS 360M is damaged, do not start pump(s) until a new Drainsafe
Installation:
®
DS 360M. Insert the other two matching OEM supplied screws,
DS 360M if screws are not secured properly. Install the next screw size larger
®
®
DS 360M
DS 360M
®
®
DS 360M cannot be moved side to side
®
DS 360M install.
®
DS 360M screw ports (5.5 to
®
DS 360M are not flush and tight
®
DS
DS 360M unit is