Installation
Water Connection
•
Water connections are labelled on the
service panel.
•
Isolation valve must be installed at the
water supply outlet.
•
CWI-1: The Combi oven requires
filtered water supplied to its steam
generation system.
Water pressure must be150-350 kPa
(22-65 psi) at oven connection.
•
CWI-2:The Combi oven requires
unfiltered water supplied to its wash
system.
Water pressure must be150-350 kPa
(22-65 psi) at oven connection.
Minimum flow rate:
10LPM - 6,10,10x2 tray oven.
20LPM - 20,40 tray oven.
BWT Filter Supplied Connectors:
•
A: Manifold fitting with 1 cap x1
•
B: Non-Return Valve x1
•
E: 3/4 BSB Hex Nipple x1
RO Filter Supplied Connectors:
•
D: Manifold fitting with 2 caps x1
•
E: Non-Return Valve x1
•
F: 3/4 BSB Hex Nipple x1
Due to continuous product research and development,
the information contained herein is subject to change without notice.
www.stoddart.com.au
www.stoddart.co.nz
CWI-1
CWI-2
Filtered Water
Non Filtered Water
150-350 kPa
(22-65 psi)
Filtration
No Filtration
System
Refer to specific
installation guide
Minimum Flow Rate
supplied with the
10LPM flow rate
water filter
6,10,10x2 tray oven
20LPM flow rate
20,40 tray oven
Supplied
Connectors
Water Flow
Direction
Water Supply
With
Isolation Valve
Page 8
150-350 kPa
(22-65 psi)
System
BWT Filter
A
B
C
RO Filter
D
F
E