AirStage ASUB24RLAV Manual de instrucciones - Página 3

Navegue en línea o descargue pdf Manual de instrucciones para Aire acondicionado AirStage ASUB24RLAV. AirStage ASUB24RLAV 8 páginas. Indoor unit (wall mounted type)
También para AirStage ASUB24RLAV: Manual de instalación (17 páginas)

AirStage ASUB24RLAV Manual de instrucciones
(7)
FILTER Indicator Lamp (red): It lights on if the fi lter became dirty.
Clean the fi lter referring to "CLEANING AND CARE". It lights off
when RESET button is pressed after cleaning.
(8)
Intake Grille
(9)
Air Filter
(10)
Airfl ow Direction Louver
(11)
Right-Left Louver (behind Airfl ow Direction Louver)
(12)
Drain Hose
(13)
Air cleaning & deodorizing fi lter
Control unit (optional)
Wireless Remote
Wired Remote
Controller
Controller
For operation method, please refer to the Operating Manual of each
device.

MANUAL AUTO OPERATION

Use the MANUAL AUTO operation in the event the remote control unit is
lost or otherwise unavailable.
CAUTION!
Do not press the MANUAL AUTO button with wet hands or pointed ob-
jects, otherwise an electric shock or malfunction may occur.

Starting Operation

Press the MANUAL AUTO button on the operating
control panel.
The operation can be set in the following setting.
Operating mode
AUTO:
When Auto mode cannot be selected, it will
operate in the same mode as the other indoor
unit in the same system. (When other indoor
unit in the same system doesn't operate, the air
conditioner will operate in cooling.)
Fan speed
AUTO
Setting temperature
74 °F (23 °C)

Stopping Operation

Press the MANUAL AUTO button on the operating
control panel.
ADJUSTING THE DIRECTION OF
AIR CIRCULATION
The vertical wind direction can be controlled with the control unit. The
horizontal wind direction can be manually set by adjusting Right-Left
Louvers.
Vertical direction
(1)
(2)
(3)
(4)
Cooling & Dry : (1), (2), (3), (4)
Heating :
(1), (2), (3), (4)
Horizontal direction

OPERATING TIPS

Simple Remote
Controller

Operation and Performance

About priority state and standby state
Multiple indoor units can be connected within the same system.
Depending on the system, choice of operating mode are limited.
Cooling priority
state
Heating priority
state
Standby state
Low ambient cooling
When the outdoor temperature drops, the outdoor unit's fans may
switch to Low Speed, or one of the fans may stop intermittently.
Heating performance
Heating mode operates on the heat-pump principle, absorbing heat
from outdoor air and transferring that heat indoors. As a result, the
operating performance is reduced as outdoor air temperature drops.
If you feel that insuffi cient heating performance is being produced, we
recommend you use this air conditioner in conjunction with another
type of heating appliance.
Heating mode heat your entire room by recirculating air throughout the
room, with the result that some time may be required after fi rst starting
the air conditioner until the room is heated.
Microcomputer-controlled automatic defrosting
When using the Heating mode under conditions of low outdoor air
temperature high humidity, frost may form on the outdoor unit, result-
ing in reduced operating performance. In order to prevent this kind of
reduced performance, this unit is equipped with a Microcomputer-con-
trolled automatic defrosting function. If frost forms, the air conditioner
will temporarily stop, and the defrosting circuit will operate briefl y (for
about 4 to 15 minutes).
During Automatic Defrosting operation, the OPERATION indicator
lamp (green) will fl ash.
Oil recovery operation
Periodically, the oil recovery operation is performed in order to return
compressor oil to the outdoor unit.
During oil recovery operation, the OPERATION indicator lamp (green)
will fl ash (for about 10 minutes).
Knob (3 places)
When the other indoor units within the same system
operate in cooling or dry mode, heating can not be
selected at the same time.
When the other indoor units within the same system
operate in heating mode, cooling and dry mode can
not be selected at the same time.
The standby state activates when 2 or more indoor
units start up at the same time in different mode.
Any indoor unit other than priority mode will wait in
standby state until priority mode changes (operation
starts as soon as priority is switched).
At this time, the operation indicator lamp (green)
lights up and the timer indicator lamp (red) fl ashes.
Right-Left Louvers
Knob
En-2