AirStage ASYA24GBCH Manual de instrucciones - Página 2
Navegue en línea o descargue pdf Manual de instrucciones para Aire acondicionado AirStage ASYA24GBCH. AirStage ASYA24GBCH 8 páginas. Indoor unit (wall mounted type)
OPERATING MANUAL
PART NO. 9377772299
VRF system indoor unit (Wall mounted type)
CONTENTS
SAFETY PRECAUTIONS ....................................................................... 1
NAME OF PARTS .................................................................................. 1
MANUAL AUTO OPERATION ............................................................... 2
ADJUSTING THE DIRECTION OF AIR CIRCULATION ........................ 2
OPERATING TIPS ................................................................................. 2
CLEANING AND CARE.......................................................................... 3
TROUBLESHOOTING ........................................................................... 4
SPECIFICATIONS .................................................................................. 5
SAFETY PRECAUTIONS
● Before using the appliance, read these "PRECAUTIONS" thoroughly
and operate in the correct way.
● The instructions in this section all relate to safety; be sure to maintain
safe operating conditions.
● "WARNING" and "CAUTION" have the following meanings in these
instructions:
This mark indicates procedures which, if im-
WARNING
properly performed, might lead to the death or
serious injury of the user.
This mark indicates procedures which, if im-
CAUTION
properly performed, might possibly result in per-
sonal harm to the user, or damage to property.
PRECAUTIONS ON USE
WARNING
● Do not keep exposing oneself to the direct wind of air conditioner for a
long time.
● Do not insert fingers or objects into the outlet port or intake grilles.
● Except for EMERGENCY, never turn off main as well as sub breaker
of the indoor units during operation. It will cause compressor failure as
well as water leakage.
First, stop the indoor unit by operating the control unit, converter or
external input device and then cut the breaker.
Make sure to operate through the control unit, converter or external
input device.
● If the power supply cord of this appliance is damaged, it should only
be replaced by the authorized service personal, since special purpose
tools and specified cord are required.
● If any refrigerant happens to leak, extinguish any flames, ventilate the
room and get in touch with authorized service personnel.
CAUTION
● Provide occasional ventilation during use.
● Do not use in applications involving the storage of foods, precision
equipment, or art works.
● Do not place animals or plants in the direct path of the airflow.
● Do not direct airflow at fireplaces or heating apparatus.
● Do not block or cover the inlet port and outlet port.
● Do not climb on, or place objects on, the air conditioner.
● Do not set flower vases or water containers on top of air conditioners.
● Do not hang objects from the indoor unit.
● Do not place anything below the indoor unit that should not get wet.
● Always turn off the electrical breaker whenever cleaning the air condi-
tioner or the air filter.
● Do not pour water or cleaning solvent on the unit directly, or wash the
unit with them.
● Do not expose the air conditioner directly to water.
● Do not operate the air conditioner with wet hands.
● Check the condition of the installation stand for damage.
● Operate only with air filters installed.
En-1
● Do not drink the water drained from the air conditioner.
● Do not apply any heavy pressure to radiator fins.
● Do not use inflammable gases near the air conditioner.
● Do not touch the piping during operation.
● Ensure that any electronic equipment is at least 1 m away from either
the indoor or outdoor units.
● This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of ex-
perience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for
their safety. Children should be supervised to ensure that they do not
play with the appliance.
Note:
Switching the operating mode in the heat recovery system may require
some time to prepare for operation. Please note that this is not a fault.
PRECAUTIONS ON INSTALLATION
CAUTION
● Do not attempt to install this air conditioner by yourself.
● This unit contains no user-serviceable parts. Always consult authorized
service personnel for repairs.
● When moving, consult authorized service personnel for disconnection
and installation of the unit.
● The unit must be grounded.
● Make sure drain work is implemented properly for drainage.
● Avoid installing the air conditioner near a fireplace or other heating
apparatus.
● When installing the indoor and outdoor units, take precautions to pre-
vent access by infants.
NAME OF PARTS
(10)
(13)
(11)
(8)
(1) Operating Control Panel
(2) MANUAL AUTO button: This is used to operate it while remote
controller is not available.
(3) Indicator Lamps
(4) Remote Control Signal Receiver: This is the place to receive the
signals from the remote controller.
(5) OPERATION Indicator Lamp (green) It lights on while operating.
(6) TIMER Indicator Lamp (orange) It lights on while timer is working.
(7) FILTER Indicator Lamp (red) It lights on if the filter became dirty.
Clean the filter referring to "CLEANING AND CARE". It lights off
when FILTER RESET button of Remote Controller is pressed after
cleaning.
(8) Intake Grille
(9) Front Panel
(10) Air Filter
(11) UP/DOWN Airflow Direction Louvers
(12) Moving Diffuser
(13) Right-Left louver (behind Airflow Direction Louver )
(14) Drain Hose
(15) Air Cleaning Filter
(15)
MANUAL
(8)
AUTO
(9)
(1)
(3)
(14)
(12)
(2)
(5)
(6)
(7)
(4)