Section 6 - Limit Switch Adjustments
Standard and Quiet Motors
Caution: Unit ships without limits. Limits will need to be set
before the unit is operated. Always be prepared to shut off
manually when new adjustment is being tested.
Push Button Limits
1. Fully depress both limit switch push buttons, then operate
wall switch to make sure system works properly.
2. Raise shade to desired "UP" stop position.
3. Set upper limit by depressing proper
4. Lower shade to desired "DOWN" stop position.
5. Set lower limit by depressing proper
Screw-Type Limits
6. Determine which direction of fabric travel corresponds with arrows on motor.
7. Operate shade to desired "down" stop position.
Set limit by turning proper socket toward "+" to lower limit, and "-" to raise it.
8. Operate shade to desired "up" stopping position.
Set limit by turning proper screw toward "-" to raise limit, and "+" to lower it.
Please Note: Each full rotation of the limit screw equals approximately 5/ 8 "
which may require rotating the limit screw several times.
Section 6.2 - Limit Adjustments
For limit setting instructions on these motors, see instructions packaged with the RS485 Address/Limit Setting Tool
Section 6.3 - Limit Switch Adjustments
Programming Instructions
1. Connect power to one motor. Select a transmitter channel to assign motor. Hold UP & DOWN buttons until motor jogs, then release.
2. Check motor direction. To reverse motor direction, hold MY/STOP button for 5 seconds until motor jogs. Check direction again.
Please note: Failure to complete Step 2 before Step 3 can only be corrected with a motor reset
3. Move motor to upper limit position. Hold MY/STOP & DOWN buttons until motor moves down, then release. Use UP &
DOWN buttons to move shade to correct lower limit and press MY/STOP.
4. While motor is at lower limit, hold UP & MY/STOP buttons until motor moves up, then release. The shade should move
to upper limit and stop.
5. Next, hold MY/STOP button for five seconds until motor jogs.
6. Put motor into USER MODE by pressing small programming button
7. Disconnect power to this motor and move to next motor in installation and start with step 1.
8. Reconnect motor to power when all motors are programmed.
Setting an Intermediate Stop - Shade MUST BE in USER mode.
1. Move shade to desired mid-point location and hold MY/STOP button until motor jogs.
2. To test, press the MY/STOP button when motor is standing still. The shade will move to that intermediate location.
3. To delete an intermediate stop, go to the intermediate stop and hold the MY/STOP button until motor jogs.
Add a Channel - Shade MUST BE in USER mode.
1. Select channel currently operating motor, then hold programming button until motor jogs.
2. Select new channel to add to motor, then hold programming button until motor jogs.
3. The motor should now work on both the old and new channel.
Delete a Channel - Shade MUST BE in USER mode.
1. Select channel operating motor that you want to keep, then hold programming button until motor jogs.
2. Select channel to remove, then hold programming button until motor jogs. Motor should now only work on channel
kept from Step 1.
Adjust Limits in User Mode
1. Move motor to limit
(upper or lower)
2. Hold UP & DOWN buttons until motor jogs.
3. Move motor to its new limit location and hold MY/STOP button until motor jogs.
Reset Motor
1. Disconnect power for 5 seconds and reconnect to power for 15 seconds. Disconnect power for 5 seconds, then
reconnect to power and leave connected. Shade should roll down a few inches and stop.
2. Hold programming button
Motor is now reset and ready to be programmed.
- Face Mount
®
push button.
(back)
push button.
(front)
(RS485 Motors)
(RTS Motors)
to be changed. Shade must move to previously set limit and will stop automatically.
for 15 seconds. Motor will jog up and down once; pause and then jog a 2nd time.
(see fig. 1)
Caution:
- Be sure all switches are in "off"
position before adjusting limit
switches.
- Shade may be damaged by
running shade fabric up too far
and exposing roller.
- If using a group control system,
each limit switch must be set
prior to connecting to system.
- Motor must be installed so limit
switches are pointed down or
accessible.
of shade travel,
(16mm)
(see Section 6.6)
on the back of transmitter until motor jogs.
(see fig. 1)
FRONT
Front
page 6 of 10
Back
GLASS SIDE
PUSH BUTTON LIMITS
Standard right-hand
ROOM SIDE
motor configuration shown
ROOM SIDE
Front
Front
Back
Back
GLASS SIDE
Bottom View
GLASS SIDE
SCREW-TYPE LIMITS
Standard right-hand
motor configuration shown
ROOM SIDE
+
ROOM SIDE
Front
Side View
+
Front
Back
+
Screws
Back
GLASS SIDE
+
Bottom View
GLASS SIDE
Bottom View
Caution: DO NOT allow the hem bar to hit the upper
roller or fascia. This will damage the unit.
Screws
Side View
.
Screws
(part# C156.241)
Side View
.
FRONT
UP
STOP
DOWN
LED Lights
Programming
Button
Channel
Selector
BACK
Bottom View
+
+
Side View
Bottom View
Side View
UP
STOP
DOWN
LED Lights
Programming
Button
Channel
Selector
Pen