Drawmer M-Clock Plus DMS-5 Manual del usuario - Página 8

Navegue en línea o descargue pdf Manual del usuario para Media Converter Drawmer M-Clock Plus DMS-5. Drawmer M-Clock Plus DMS-5 10 páginas. Aes grade 1 master clock and dual sample rate converter

M-CLOCK Plus DMS-5 GENERAL INFORMATION

IF A FAULT DEVELOPS

For warranty service please call Drawmer Electronics Ltd. or
their nearest authorised service facility, giving full details of
the difficulty.
A list of all main dealers can be found on the Drawmer
webpages.
On receipt of this information, service or shipping instructions
will be forwarded to you.
No equipment should be returned under the warranty without
prior consent from Drawmer or their authorised representative.
For service claims under the warranty agreement a service
Returns Authorisation (RA) number will be issued.
Write this RA number in large letters in a prominent position
on the shipping box. Enclose your name, address, telephone
number, copy of the original sales invoice and a detailed
description of the problem.
Authorised returns should be prepaid and must be insured.
All Drawmer products are packaged in specially designed
containers for protection. If the unit is to be returned, the original
container must be used. If this container is not available, then
the equipment should be packaged in substantial shock-proof
material, capable of withstanding the handling for the transit.

CONTACTING DRAWMER

Drawmer Electronics Ltd., will be pleased to answer all
application questions to enhance your usage of this
equipment. Please address correspondence to:
Drawmer (Technical Help line)
Coleman Street
Parkgate
Rotherham
S62 6EL
UK
Alternatively contact us by E-mail on :
Further information on all Drawmer dealers, Authorised service
departments and other contact information can be obtained
from our web pages on:
http://www.drawmer.com
8

SPECIFICATION

Internal Clock Generator
2 x Temperature Compensated Xtal Oscillators (TCXOs)
AES11 GRADE 1 Stability,
Tolerance
Phase noise
@ 24.5760 MHz to give Fs
@ 22.5792 MHz to give Fs
Word Clock Outputs
Output impedance
All outputs selectable between
AES 11 Outputs
2 x Neutrik XLR
2 x Gold Plated Phono
Sample Rate Conversion
2 x Stereo Sample
Rate Converters:
2 x Neutrik XLR AES/EBU inputs
2 x Phono SPDIF inputs
2 x TOSlink inputs
All outputs simultaneous on
THD+Noise
Display
Blue/white LCD display wth three switchable modes of
operation with mode led indicators for each:
frequency
actual frequency up to >192KHz
+/- ppm
nominal sample rate with +/- ppm error
indication for 32,44.1,48,88.2, 96 & 192KHz
+/-%
Nominal sample rate with percent pull up/
down indication for 32,44.1,48,88.2, 96 &
192KHz
Accuracy
2ppm at all sample rates up to 192KHz
0.1 Hz increments @ 48KHz sample rate
General
Power Supply:
Internal, Universal Input, 15 W
Fuse Rating
T315mA for All voltages.
CONFORMING TO: IEC127-2
Fuse Type
20mm x 5mm, Class 3 Slow - Blow
250Volt working
Dimensions:
1u, 19" Rack Mount,
482mm(W) x 44mm(H) x 145mm(D)
Weight
2.025 kg
CHAPTER 3
+/-1ppm (0-60 Celcius),
<<+/-1ppm (15-30
Celcius)
-130 dBc/Hz @ 1kHz
48, 96 & 192 kHz
44.1, 88.2 & 176.4kHz
33 ohms
44.1, 48, 88.2, 96, 176.4
and 192 kHz
110 ohm source @ 44.1,
48, 88.2, 96, 176,192kHz
75 ohm source @ 44.1,
48, 88.2, 96, 176,192kHz
full up/down conversion
from 44.1kHz to 192kHz
2 x AES/EBU XLR,
2 x SPDIF Phono,
2 x TOSLINK
> 130 dBFs