Chapter 5
The part describes how to remove the fault from the switch.

5.1 Fault Separation

The key for resolving the systematic faults is to separate the fault from the system. You
can compare what the system is doing with what the system should do to detect the
fault. You need to check the following subsystems:
Connection of the power supply
Port, cable and connection—ports on the front template of the switch and the
cables connecting these ports
5.1.1

Power Fault

Do the following checkups to help remove the fault:
Make sure that the power line is reliably connected and that the power supply
provides power normally.
Check the environmental conditions and make sure that the switch is put at a
working location with a temperature of 0 to 45℃.
 If the power supply of S2510-B provides power normally, power indicator PWR is
on, or indicator SYS flickers.
5.1.2

Faults Relative with Port, Cable and Connection

Do the following checkups to help remove the fault:
If the port of the switch cannot be linked, check whether the cable is correctly
connected and whether the peer connection is normal.
If the console port does not work after the system is started up, check whether
the console port is set to a baud rate of 9600 bps, eight data bits, no sum check
bit, one stop bit and no traffic control.

5.2 LED Description

The LED indicator shows that the switch is running. The following table shows the indicators of the
S2510-B switch and their description:
No.
Abbrev.
1
PWR
Hardware Fault Analysis
Name
Power LED
S2510-B Hardware Installation Manual
Remarks
It is on when the power supply provides power
- 16 -