AirStage UTY-RNKY Manual de instrucciones - Página 8
Navegue en línea o descargue pdf Manual de instrucciones para Controlador AirStage UTY-RNKY. AirStage UTY-RNKY 13 páginas. Wired remote controller
También para AirStage UTY-RNKY: Manual de instalación (8 páginas)
FILTER LAMP RESET
Some indoor unit models are equipped with a fi lter lamp in the indoor unit display to indicate when it is time to clean the air fi lters.
Press the "
MAINTENANCE / FILTER RESET" button for 2 seconds or more. The indoor unit fi lter lamp will go off and the fi lter
display will disappear.
ON/OFF TIMER
Instructions on heating are not applicable for the "COOLING-ONLY" models.
The timer function is not available depending on the slave unit.
To set the ON/OFF timer
1
No display
NON
OFF
TIMER
TIMER
● To cancel the timer mode
• Press the "TIMER DELETE" button to cancel the timer mode.
• The timer mode can also be canceled by changing the timer mode using the "
ADJUST" button.
En-7
Press the "
TIMER MODE /
CLOCK ADJUST" button to select
the ON timer, OFF timer or weekly
timer.
It is switched every time as shown in
the below diagram when the button
is pressed.
ON
WEEKLY
TIMER
TIMER
2
Decrement
Increment
From 1 to 24 hours
Press the "
" button or "
The timer starts automatically when an unoperated 3 seconds
is passed after the timer setting is completed.
The amount of time until the OFF timer operates that is displayed
on the timer display decreases as time passes.
The time can be changed by the Decrement/Increment buttons
after the timer is once set.
SU MO TU WE TH FR SA
ex. OFF timer set for 6 hours
" button to set the time.
TIMER MODE / CLOCK