Carlin 70200 Manual de instrucciones de instalación y funcionamiento
Navegue en línea o descargue pdf Manual de instrucciones de instalación y funcionamiento para Unidad de control Carlin 70200. Carlin 70200 9 páginas. Universal oil primary control
También para Carlin 70200: Manual de instrucciones de instalación y funcionamiento (12 páginas)

• Universal Replacement – for Carlin,
Beckett, Honeywell and ICM Controls
• On-Board LCD Screen – no special
tool needed
• Fully Programmable Settings
• 32 Cycle Fault History
• Alarm Contacts
• Communications Port
• Serviceman Reset Protection
• Blocked Vent Protection
• Built-in Pump Prime
• Recessed Spade Connectors
• Provides CAD Cell Reading in OHMS
It is important that the installation of the oil burner,
piping and fittings, safety devices, controls, electrical
wiring and equipment be done in accordance with
national and/or local regulations of the authorities
having jurisdiction over such installation.
©
Copyright 2017 — Carlin Combustion Technology, Inc.
Model 70200
Universal Oil
Primary Control
Installation and
Operating Instructions
For Use By Qualified Service Technicians Only
Power input
(red/white wire) ................................ 120 VAC, 60 HZ, 9 VA
Limit circuit input
(black wire) .............................................. 120 VAC, 60 HZ
Motor load
(orange wire) .........10 FLA / 60 LRA (reduce by valve load)
Ignitor load
(blue wire) .................................... 120 VAC, 60 HZ, 500 VA
Valve load
(violet wire) .......................................... 120 VAC, 60 HZ, 2A
Vent load ................................................................. 0.1 amp
Vent input ............................................................... 12 V, 2A
Line heater ................................................................ 1 amp
Alarm contacts (dry contacts)....................24V, AC/DC, 2A
Operating temperature limits ..................+32°F to +140°F
Storage temperature limits ...................... -40°F to +185°F
Thermostat anticipator current .......................... 0.1 A, AC
Agencies .............................. UL recognized (US & Canada)