Connecting 12 V AC cable to the
outdoor unit
5.3
COMMUNICATION BETWEEN THE AIR CONDITIONER AND THE
1-2,3 KW LXCD BOX CONTROL UNIT

5.3.1 SWITCHING THE AIR CONDITIONER ON

After turning on the air conditioner by remote control (RC) or using a mobile phone application, the
direct current (DC) water heating in the LX water tank disconnects automatically. The current (DC) in
the 1,2,3 kW LXDC BOX control unit automatically redirects to outlet no. 2, where there is a
connecting cable between the 1,2,3 kW LXDC BOX control unit and the LX air-conditioning unit. After
about 10 seconds, the LX air conditioner starts drawing ecologically produced electricity from the
photovoltaic panels.

5.3.2 SWITCHING THE AIR CONDITIONER OFF

The air conditioner can be turned off by remote control (RC) or using a mobile phone application in
real time, or if the time elapses after setting the timer. The air conditioner works for some time even
after switching off the power in energy-saving mode, since it is very important to equalize the
temperature of the LX air conditioner and that of the ambient air and thus avoid condensation of
humidity and possible formation of mildew on the heat exchanger of the air-conditioning unit.
After turning off the LX air conditioner the 1,2,3 kW LXDC BOX control unit automatically redirects
electricity (DC) from the solar panels back into the water tank, where the electricity is further stored
in the form of heat.
That redirection is time delayed:
In heating mode: by 3 minutes
In cooling mode: by 7 minutes
See more in the wiring diagram, p. 7
Energy can also be redirected in automatic mode. If the room temperature approaches the set
temperature, the air conditioner gradually reduces its output to shutdown when the 1,2,3 kW LXDC
BOX control unit automatically redirects the power to the hot water tank. When the temperature
drops (increases) in the room, the air conditioner re-activates automatically and the 1,2,3 kW LXDC
BOX control unit redirects the power to operate it.
Connecting 12 V AC cable to the 1-2,3
kW LXDC BOX control unit
- 12 -