Carlon JLP1000 Instrucciones de instalación y funcionamiento - Página 2

Navegue en línea o descargue pdf Instrucciones de instalación y funcionamiento para Instrumentos de medida Carlon JLP1000. Carlon JLP1000 2 páginas. Plastic no-lead series water meter

Carlon JLP1000 Instrucciones de instalación y funcionamiento
JLP
Meter Installation Instructions
®
1. Flush the line thoroughly after plumbing changes to eliminate the
possibility of foreign contaminants reaching the meter.
2. Install meter horizontally with the register facing up and the inlet
port facing the supply water line.
3. Operating pressure maximum of 100 psi.
4. It is recommended that if there is any possibility that the water
supply contains foreign contaminants, a strainer should be
installed between the water supply and the meter.
5. It is not recommended that the meter be run for long periods of
time at the maximum flow rating as excess wear will result and
the life of the meter will be reduced.
6. To reduce potential harmful effects to equipment from water
hammer caused by quick closing valves, it is suggested that you
purchase and install a slow-closing solenoid valve.
7. Protect the meter from freezing and from heat in excess of 122° F.
8. Protect meter from any backflow of water opposite indicated
direction of flow.
9. For outdoor installation, protect meter (and remote counter) from
direct exposure to the elements.
Straight, unobstructed pipe section in front of the meter
should be as follows:
Inlet Path - One Bend = 10 x Diameter of pipe
Valves (check, gate, etc.) = 12 X Diameter of pipe
Two Bends or One Tee and one bend(s) at random =
25 x Diameter of pipe
Straight, unobstructed pipe section downstream of meter =
5 x Diameter of Pipe
JLP
Model
Size
Length
⅝" X ¾"
JLP0750
JLP1000
¾" X 1"
Meter Capacities
Maximum
Model
Size
Capacity
⅝" X ¾"
JLP0750-G
22
JLP1000-G
¾" X 1"
50
⅝" X ¾"
JLP0750-L
83.28
JLP1000-L
¾" X 1"
189.27
JLP
Contact Settings Available:
®
Reed Switch / SINGLE:
Reed Switch / DUAL:
Reed Switch / QUAD:
Note: Plastic meter couplings are provided.
Meter Housing: Engineered reinforced plastic (nylon).
Operating Pressure Range: Maximum 100 psi
Temperature Range: 35°F - 122°F
Register Options: U.S. Gallons, Cubic Feet, and Liters.
Series
®
Height
Weight
7½"
4¼"
1.4 lbs.
10¾"
5"
1.8 lbs.
Normal
Flow
Flow
12
¼ - 22
GPM
GPM
25
¾ - 50
GPM
GPM
45.42
.95 - 83.28 LPM
LPM
LPM
94.64
2.84 - 189.27 LPM
LPM
LPM
JLP0750
1 PPG / 1 PPL
JLP1000
JLP0750
2 PPG / 2 PPL
JLP1000
JLP0750
4 PPG / 4 PPL
JLP1000
Range
GPM
GPM