GENERAL INSTALLATION INSTRUCTIONS

PREPARATION
A: GENERAL
 Carefully unpack the hood but do not remove any
protective film until after installation to avoid
accidental damage or scratching. Place filters
somewhere safe for the same reason.
 Check for damage, and lay out the hood pieces and
parts.
 Range hoods do not come with wall or ceiling screws,
as the type of structure determines the type of screws.
Check that you have the right tools. In addition to
marking and measuring tools, a hammer, screwdrivers,
pliers and scissors, you may need sheet metal sheers,
and wire strippers. Safety glasses are recommended.
WALL MOUNTED RANGE HOOD INSTALLATION
The Arca wall mounted range hoods can only be ducted outside -
exhaust mode
DUCTED EXHAUST MODE INSTALLATION (Pic 7a, 7b)
 In exhaust mode hood models, the kitchen vapours are purified by
the metal anti-grease filters and carried outside through a ducting
system.
 To begin, choose where the ductwork should run between the hood
and the outside of your home. The straighter and shorter the duct run,
the more efficient the performance.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL
DUCTWORK.
Note: Range hoods pictured in this manual are generic to represent
all models.
B: ELECTRICAL CONNECTION
 This range hood must be grounded. If the dwelling wiring
is not 2-wire with a ground wire, a ground must be
provided by the installer.
 Install a 5.08 X 10.16 cm (2" X 4") wall outlet box and 3-
blade 125 Volts, 15 amp grounded receptacle.
 Use wire nuts to connect incoming ground, neutral and
hot.
 Push wires into the junction box and replace cover. Be
sure wires are not pinched.
C- INSTALLATION DISTANCE
 Hood should be placed at a minimum distance from top of
range of:
– 61 cm (24") for electric cooking surface
76 cm (30") for Gas Cooking Surface
Pic 7a
Pic 7b
4