8
The required minimum mounting depth of a clamp
is 15mm.
Elegante Modules punctually supported with clamps
on the long sides, mounted according to the rules, can
bear pressure and soak loads till 5400Pa, according to
IEC 61215 (Crystalline silicon terrestrial photovoltaic
(PV) modules – Design qualification and type appro-
val), without compromise the functional capabilty of
the PV module.

8 Electrical installation

8 . 1

Personal protection

High DC voltages during storage, installation, ope-
ration and maintenance . Risk of fatal electric shock!
aleo modules may only be installed by qualified
technicians with a high level of expertise (see sample
of cennection
Figure 8A
Never touch the electrical connections of a solar mo-
dule under any circumstances, not even if you have
disconnected the photovoltaic generator.
Electric arcs are generated when electrical compo-
nents are connected or disconnected incorrectly .
Before you carry out any work on electrical compo-
nents, disconnect the photovoltaic generator.
Figure 8B
Contact with live parts due to defective insulation or
damaged / fallen off junction box covers.
Figure 8C
Do not touch damaged parts with your bare hands.
Use protective clothing and suitable, insulated tools.
aleo solar GmbH | Marius-Eriksen-Straße 1 | 17291 Prenzlau | Germany | [email protected]
).
Installation Manual GG Elegante Rel. 1.5, 01/2022, EN
Copyright © 2021 aleo solar GmbH
7A
7B
fG ≤ lG /100
max . 15mm
l
G
7C
≥ 80mm & ≤ 300mm
l
W