CONNECTIONS - HARNESS
---
MAIN HARNESS WIRING DESCRIPTIONS
Main Harness 8-Pin 14-16 Gauge
Purple
OUTPUT
Connect this output to a data bypass module or vehicle's Negative(-) triggered Starter input. This output
is rated for 500mA. DO NOT use this output to drive Starter Motor's Negative(-) side directly.
White
OUTPUT
Connect this output to vehicle's Starter input at the ignition switch.
IMPORTANT: Ensure that the ignition current is not rated more than 30A. Connect to external relay with
higher current rating if required.
Red
INPUT
Connect to a constant +12V supply wire at the ignition switch. Ensure that the OEM input power wire is
fused for more than 30A.
Note: When no suitable +12V source available, connect to vehicle's power supply at the fuse junction
box or connect directly to the B+ terminal on the battery.
Blue
OUTPUT
If applicable, connect this output wire to vehicle's secondary ignition (ON 2) input at the ignition switch.
This output will be +12V in ON and RUN state and OFF during Start (crank) State.
Green
OUTPUT
Connect this output wire to vehicle's primary ignition (ON) input at the ignition switch.
Black
INPUT
Connected to bare, unpainted metal on chassis. It is recommended to use a factory ground bolt rather
than a self-tapping screw. Screws tend to get loose or rusted over time and lead to erratic electrical
problems.
Red
INPUT
Connect to a constant +12V supply wire at the ignition switch. Ensure that the OEM input power wire is
fused for more than 30A.
Note: When no suitable +12V source available, connect to vehicle's power supply at the fuse junction
box or connect directly to the B+ terminal on the battery.
Yellow
OUTPUT
Connect this output wire to vehicle's accessory (ACC) input at the ignition switch. This output will be
OFF during START (crank) state.
Ignition Outputs State Table:
Following table shows state of the ignition outputs when system is in ACC, ON, START and RUN mode:
System State
OFF
Ready
ACC
ON
Step On Brake
START (Crank)
RUN (ON)
4
© Copyright Advanced Keys Inc. 2013. All Rights Reserved.
-
500mA
Negative START
+
30A
Positive START
+
30A
Battery +12V
+
30A
ON 2 / 2nd Ignition Output
+
30A
ON 1 / Primary Ignition Output
-
Ground
+
30A
Battery +12V
+
30A
ACC
Status LED
All Off
Amber
Green
Green (Flashing)
Amber (Flashing)
All Off
Backlight Only
OPTIONAL
ACC
ON 1
-
-
-
-
12v
-
12v
12v
No Change to Any Output
-
12v
12v
12v
ON 2
START
-
-
-
-
-
-
12v
-
-
12v
12v
-