También para Bosch 300 Series: Manual de instrucciones (40 páginas), Manual del usuario (21 páginas), Manual de instalación (6 páginas), Manual de instalación (36 páginas), Manual de uso y mantenimiento / Instrucciones de instalación (40 páginas), Manual de instrucciones (50 páginas), Manual de inicio rápido y seguridad (7 páginas), Manual de instalación (28 páginas), Manual de inicio rápido (7 páginas), Manual de uso y mantenimiento (32 páginas), Manual de inicio rápido y seguridad (7 páginas), Manual de servicio (36 páginas), Manual de inicio rápido y seguridad (13 páginas)

Bosch 300 Series Manual de instalación
Insert the two remaining self-aligning screws through
4.
outer top cabinet holes. Turn two full turns on each
screw.
Tighten center screw completely.
5.
Tighten the outer two screws completely to the top of
6.
the microwave oven.
Note: While tightening screws, hold the microwave
oven in place against the wall and the top cabinet.
Install grease filters by sliding them into the side slots,
7.
then pushing up and toward oven to lock (image
shows bottom view of appliance).
Duct Pieces
Rectangular-to-Round Tran-
sition Adaptor*
Wall Cap
12

Hood exhaust

When venting exhaust to the outside, hood exhaust ducts
will be required. Read the following carefully.
Note: It is important that venting be installed using the
most direct route and with as few elbows as possible.
This ensures clear venting of exhaust and helps prevent
blockages. Also, make sure dampers swing freely and
nothing is blocking the ducts.
The hood exhaust has been designed to mate with a
standard 3¼" x 10" (82 x 254 mm) rectangular duct. If a
round duct is required, a rectangular-to-round transition
adaptor must be used. Do not use less than a 6"
(152 mm) diameter duct.
For satisfactory air movement, the total duct length of
3¼" x 10" (82 x 254 mm) rectangular or 6" (152 mm)
diameter round should not exceed 120 equivalent feet
(36.5 m).
Elbows, transitions, wall and roof caps etc. cause
additional resistance to airflow and are equivalent to a
section of straight duct which is longer than their actual
physical size. When calculating the total duct length, add
the equivalent lengths of all transitions and adaptors plus
the length of all straight duct sections. The chart below
shows you how to calculate total equivalent ductwork
length using the approximate feet of equivalent length of
some typical ducts:
x
5 ft (1.5 m)
x
40 ft (12.2 m)
x
Number used
=
Equivalent Length
=
=
Total Ductwork =