Bosch Logixx 10 WTB76556GB Manual de instrucciones e instrucciones de instalación - Página 27

Navegue en línea o descargue pdf Manual de instrucciones e instrucciones de instalación para Secadora Bosch Logixx 10 WTB76556GB. Bosch Logixx 10 WTB76556GB 32 páginas.

Bosch Logixx 10 WTB76556GB Manual de instrucciones e instrucciones de instalación

Troubleshooting

Before calling the customer service,
check whether you can rectify the fault
yourself by means of the following
table.
If a fault cannot be rectified or a repair
is required:
Problem
Dryer does not start.
Start/Pause indicator light does not
illuminate.
illuminate.
Program has been interrupted.
A warning signal is emitted and the
display shows E:01 and/or the Filter
display shows E:01 and/or the Filter
indicator light flashes.
Drum light does not function.
Start/Pause indicator light does not
illuminate. Anti Crease/end indicator
illuminate. Anti Crease/end indicator
lights.
The display shows 0:00.
1. Set program selector to Off.
2. Turn off the circuit breaker.
3. Pull the mains plug out of the
socket.
4. Call customer service
(see Page 28).
Possible cause
Main plug not inserted at all or not inserted correctly. Insert main plug correctly.
A fuse of power supply has tripped.
Start/Pause button not pressed.
No program selected.
Door not closed.
In Time Programs duration not chosen.
Ambient temperature below 5 °C.
Filter dirty.
Exhaust air duct is blocked.
Fault in program sequence or malfunction.
The room/cabinet is not adequately ventilated.
No program selected.
Light bulb defective, light bulb burned out.
No power supply.
Light bulb is loose.
Fault in program sequence or malfunction.
Remedial action
Replace/switch on fuse.
Press Start/Pause button.
Select program.
Close door.
Chose time via Select button.
Increase room temperature.
Clean filter as described on Page 25.
Switch off/switch on again.
Clean exhaust air extraction.
Switch off/switch on again.
Switch off dryer, leave to cool down for 30 min.
Switch on again.
Restart program.
Provide an adequate supply of fresh air.
Switch off/switch on again.
Select program.
Change light bulb, see Page 26.
Guarantee power supply.
Tighten light bulb. Remove and reinstall the cover
as directed on Page 26.
Switch off dryer, leave to cool down for 30 min.
Switch on again.
Switch on again.
Restart program.
27