ATTENTION:DANGER OF BEEN BURNT
When burner in operation, combustion is severe, so the burner must be fixed. Hoses or
cables in area of the combustion system must be suitable for high temperature, to prevent
high temperature failure or cause safety accidents. Burners should be periodically
inspected and cleaned. Copper wire brush may be used, if necessary, to clean burner head.
The burner system should be checked twice a year for safety operation.
Burner commissioning shall take care of ignition position, minimum and maximum output
position. Following interlocks will cause emergency stop, including gas low pressure, high
pressure or low combustion air pressure, as well as emergency stop is trigged, the main
power is out, UV signal failure or kiln safety conditions (such as high temperature limit, flue
system opening, etc.) will cause the burner lockout. Users need to know the maintenance
interval recommended by the manufacturer and the interval specified by national laws,
whichever is shorter.
4.
Description
SRB series burner is suitable for air and natural gas combustion heating in radiant tube.
The burner is composed of rear cover and burner body. The rear cover is equipped with
accessories such as a gas orifice, a pressure measuring taps, a peep sight.
Spark plug is fixed on rear cover and flame rod or UV scanner to be used for flame
monitoring.
The burner body has combustion air inlet and exhaust gas connection. The material for
burner body is die-casting aluminum alloy and adopts a double-layer structure to reduce
the temperature. Burner nozzle and recuperator are installed on the burner body, and the
burner is connected to the furnace wall or the radiant tube through the installation flange
on the burner body. The air inlet is equipped with an air hole plate, and the flue gas channel
is equipped with a thermal insulation fiber.
Recuperator is used to recover the waste heat of the flue gas and preheat the combustion
air. According to different working conditions, there are two materials available: metal and
silicon carbide. A large number of fins are arranged on the inner and outer surfaces of the
recuperator, and protrusions are arranged on the inner and outer surfaces of the ceramic
recuperator to enhance the heat exchange efficiency. Burner structure refer to Fig 1.
Spark plug with
cooling air inlet
Anderson Thermal Soluions(Suzhou)Co., Ltd
Combustion air inlet
Exhaust gas outlet
Installation flange
Combustion air
backup inlet
Fig 1. Burner parts (Metal recuperator as reference)
2