✔ If the antenna is fixed outside on a pole, it must be link to the ground. A surge protector must be installed between
the antenna and the ARM radio modem.
✔ Respect the norms, using recommended antenna cables to stay in the authorized emission limits (according to the
channel: 5mW, 25mW or 500mW).
1. DESCRIPTION
N°
1
2
3
4
2. INSTALLATION
2.1. Antenna
The ARM-IO is delivered with a small ¼ wave antenna. If you want better performance, you can use one of these antennas:
✔ ANT868-12FSC (Antenna ½ wave): this antenna can be directly mounting on the l'ARM-IO.
✔ ANT868-12S-L (Antenna ½ wave): no needs to metallic planfloor, it can be mounting directly on a polyester support of a
vehicle or above a PVC case.
For best results, we recommend to install the two antennas in line of sight and as high as possible.
2.2. Communication modes
L'ARM-IOD-works in 3 modes:
- Mirror mode
- Modbus slave
- Sensor mode(datalogging)
See the use manual for functioning
choice
Connection
GND
INP2
INP1
GND
The mirror mode allowed the report of contacts or
analogical values to a distant radio module, which can be
an ARM-D or an ARM-X. Then the radio module can
centralize the values from several distant ARM-IOD-LP.
Notice technique complète sur
FRQIG_ARM-IOD-LP
Page2/4
M12 connector pin out :
2
3
Input/output type
Input
Input
www.atim.com
1
4
Designation
Masse
Logic input 2
Logic input 1
Masse
In
modbus
slave
configuration
registers
following functions are available:
- Reading logic input
- Reading/writing memorized input
- Reading voltage power supply
- Reading RSSI value
- Reading/writing rising edge and
falling edge (see use manual)
mode,
all