Comnet CLFE4+2SMSPOEC Manual de instalación y funcionamiento - Página 5

Navegue en línea o descargue pdf Manual de instalación y funcionamiento para Interruptor Comnet CLFE4+2SMSPOEC. Comnet CLFE4+2SMSPOEC 7 páginas. 10/100tx drop/insert/repeat 4tx/2ex self-managed switch with poe+

Comnet CLFE4+2SMSPOEC Manual de instalación y funcionamiento
INSTALLATION AND OPERATION MANUAL
Table 4 – Approximate Maximum Extended Distances¹
Media
Extended Port Data Rate
Extended Distance
1
1
Distance figures are obtained using in-house testing mirroring installations. Factors such as coaxial/copper cable quality, the number of connectors/
splices in the cable run, the use of PoE, and environmental conditions encountered within the installation may affect the actual transmission
distance, and should be taken into consideration.
Table 5 – Troubleshooting Guide
Problem
Indicating LEDs not lighting
No Communication
Bad Video or Data
Units not reaching estimated max
distances over COAX or UTP
Figure 3 – DIP Switch Settings
TECH SUPPORT: 1.888.678.9427
COAX - RG59/U
10M
100M
5,000 ft
2,000 ft
1,524 m
610 m
Steps to Take
Check that power is properly applied to the unit using the correct connector pair.
Check Ethernet Link LEDs, Extended Link LEDs, All Connections, Local/Remote switch is set properly.
Verify that Local units are installed at the head end and that Remote units are installed in the field.
Verify that the Data Rate switches are set to the same data rate on both the Local and Remote units.
Make sure Data Rate and 1/4 Pair Switches are set properly, and the extended distance is within specifications (see Table
4 – Approximate Maximum Extended Distances).
Check extended distance cable and connections. Try connection on a short cable to eliminate possibility of faulty cabling.
Check that the extended distance wire is connected to Extended Distance Port.
Verify that there is no additional equipment (e.g. surge protector) on the Extended Link. The cable should be continuous from
end to end, with no active components.
Table 6 – DIP Switch Settings
DIP Switch
L/R
CL1
10/100
1 - 4 PAIR
L/R
10/100
CL2
1 - 4 PAIR
CL1 UP LINK
UTP - 1 pair
10M
100M
3,000 ft
1,000 ft
914 m
305 m
Setting Effect
On
Unit will operate as remote / field
100 Mbps Data Speeds
1 Pair Twisted Wires
Unit will operate as remote / field
100 Mbps Data Speeds
1 Pair Twisted Wires
Enabled
CLFE4+2SMS[POE](C,U) SERIES
UTP - 4 pair
10M
3,000 ft
914 m
Off
Unit will operate as local / head-end
10 Mbps Data Speeds
4 Pair Twisted Wires
Unit will operate as local / head-end
10 Mbps Data Speeds
4 Pair Twisted Wires
Disabled
INS_CLFE4+2SMS[POE](C,U)_REV– 10/27/11 PAGE 5
100M
2,000 ft
610 m