INSTALLATION AND OPERATION MANUAL
IP CAmERA-End
InsTALLATIOn (CLFE1COAX)
Set the Remote/Local dip switch to "Remote"
mode.
Set the S1 dip switch to the appropriate rate
S1 S2
based on the maximum data rate. OFF =
10Baset; ON = 100Baset
Set the S2 switch to "On" for Master.
For systems not utilizing PoE, connect the 12VdC or 24VAC
Power Supply to the power connector of the CLFE1COAX. An
external power adapter is provided to simplify connection.
If there is no external power source connected, the
CLFE1COAX will try to detect PoE.
CAUTION: If the external power adaptor is connected
with no power applied, the CLFE1COAX will not
recognize the PoE source and the system will be
inoperative.
Connect the IP camera RJ-45 connector to the 10/100Baset
Ethernet port of the CLFE1COAX using a standard Cat5/6
cable, 100m length (max).
Connect one end of the long coax cable to the BNC
connector of the CLFE1COAX.
TECh SUPPORT: 1.888.678.9427
EThERnET swITCh/nVR-End
InsTALLATIOn (CLFE(X)COAX)
Set the Remote/Local dip switch to "Local"
mode.
Set the S1 10/100Baset dip switch to the
S1 S2
appropriate rate based on the maximum
data rate. OFF = 10Baset; ON = 100Baset
Be sure the S2 switch to is set to "Off" for Slave.
Note: The 4, 8 and 16 channel units are preset to Slave/Local
mode. No adjustment required.
Connect the 12VdC or 24VAC Power Supply to the power
connector of the selected CLFE(X)COAX If there is no external
power source connected, the selected CLFE(X)COAX will try
to detect PoE.
Connect the IP camera RJ-45 connector to the 10/100Baset
Ethernet port of the selected CLFE(X)COAX using a standard
Cat5/6 cable, 100m length (max).
Connect one end of the long coax cable to the BNC
connector of the selected CLFE(X)COAX.
the Link LEd on the 10/100 Ethernet connector should be
"ON" to indicate proper connection between the switch and
the selected CLFE(X)COAX.
the traffic LEd on the Coax side should be "ON" and flashing
to indicate proper connection.
the Link LEd (Red for 100Baset, Green for 10Baset) will be "ON"
and not flashing to indicate confirmed connection between the
CLFE1COAX and selected CLFE(X)COAX extenders.
CLFE(X)COAX