Carotron AM1000-000 Manual de instrucciones - Página 8
Navegue en línea o descargue pdf Manual de instrucciones para Hardware de red Carotron AM1000-000. Carotron AM1000-000 10 páginas. Loom takeup
6
Adjustment Procedure
WARNING! DURING CALIBRATION, THE AM-1000 WILL PRODUCE
AN OUTPUT. PLEASE DISCONNECT ANY EQUIPMENT FROM THE
DRIVE THAT COULD BE DAMAGED OR CAUSE INJURY DURING THIS
PROCESS.
1. Connect the AM-1000-XXX per the connection diagram. Place switch S1 in the
appropriate position (I or V) based on the type of external sensor.
2. If a 1/4 HP motor is used, make no connection from CN1 to CN2. If a 1/2 HP
motor is used, connect a wire jumper from CN1 to CN2.
3. With no load on the motor or machine and with the speed sensor providing
minimum signal on terminal 10, apply power to the control. Place the drive in the
RUN mode by closing a set of contacts across terminals 3 & 4. Increase the MIN
SPEED pot (P2) clockwise until the motor just begins to creep and then CCW until
the motor just stops.
4. Adjust the external sensor to provide maximum signal to terminal 10. Adjust the
MAX SPEED pot (P1) until desired maximum motor speed is obtained. Open the
contacts across 3 & 4 to stop the motor.
5. Place the drive in the JOG mode by closing the contacts across 5 & 6. Adjust the
JOG SPEED pot (P3) until desired jog motor speed is achieved. Open the
contacts to stop the drive.
6. If desired, the current limit level can be reduced by adjusting the CURRENT LIMIT
pot (P4) counter-clockwise.
8