Electrolux EGC3322 Manual del usuario - Página 12

Navegue en línea o descargue pdf Manual del usuario para Placa Electrolux EGC3322. Electrolux EGC3322 20 páginas. Electrolux hob
También para Electrolux EGC3322: Manual del usuario (16 páginas), Manual del usuario (20 páginas), Manual del usuario (20 páginas)

Electrolux EGC3322 Manual del usuario
12 www.electrolux.com
volume greater than 20 m³), but not in a
bathroom or shower room.
The minimum distance combustible mate-
rial can be fitted above the hob in line with
the edges of the hob is 400 mm. If it is fit-
ted below 400 mm a space of 50 mm
must be allowed from the edges of the
hob.
For appliances installed in the Republic of
Ireland please refer to NSAI- Domestic
Gas Installation I.S 813 Current Edition
Section 7- Permitted Locations of Appli-
ance.
8.2 Gas Connection
WARNING!
Any gas installation must be car-
ried out by a GAS SAFE REGIS-
TER installer.
Make sure that, once the hob is installed,
it is easily accessible for the engineer in
the event of a breakdown.
The manufacturer will not accept liability,
should the above instructions or any of
the other safety instructions incorporated
in this instruction booklet be ignored.
Screw the parts and tighten everything
with teflon tape, if necessary, to get the
right direction.
A)
End of shaft with nut
B)
Elbow
Connection to the gas supply should be
with either rigid or semi-rigid pipe, i.e.
steel or copper.
The connection should be suitable for
connecting to R 1/2 (1/2 BSP male
thread).
When the final connection has been
made, it is essential that a thorough leak
test is carried out on the hob and installa-
tion.
Make sure that the main connection pipe
does not exert any strain on the hob.
If you use flexible metal pipes make sure
that they agree to ISO 10380 and ISO
10807 standards. Be careful they do not
come in touch with mobile parts or they
are not squeezed. Also be careful when
the hob is put together with an oven.
Rigid connection:
Carry out connection by using metal rigid
pipes (copper with mechanical end).

8.3 Injectors replacement

1.
Remove the pan supports.
2.
Remove the caps and crowns of the
burner.
3.
With a socket spanner 7 remove the
injectors and replace them with the
ones which are necessary for the type
of gas you use (see table in "Techni-
cal Information" chapter).
4.
Assemble the parts, follow the same
procedure backwards.
A
5.
Replace the rating plate (it is near the
gas supply pipe) with the one for the
new type of gas supply. You can find
B
this plate in the package supplied
with the appliance.
If the supply gas pressure is changeable
or different from the necessary pressure,
you must fit an applicable pressure ad-
juster on the gas supply pipe.
8.4 Adjustment of minimum level
To adjust the minimum level of the burn-
ers:
1.
Light the burner.
2.
Turn the knob on the minimum posi-
tion.
3.
Remove the knob.
4.
With a thin screwdriver, adjust the by-
pass screw position.
It is important to install the elbow
correctly, with the shoulder on the
end of the thread, fitted to the hob
connecting pipe.
Failure to ensure the correct as-
sembly will cause leakage of gas.
Make sure that the gas supply
pressure of the appliance obeys
the recommended values.