12 www.electrolux.com
A
A)
The by-pass screw
• If you change from natural gas G20 20
mbar to liquid gas, fully tighten the by-
pass screw in.
• If you change from liquid gas to natural
gas G20 20 mbar, undo the by-pass
screw approximately 1/4 of a turn (1/2 of
a turn for Triple Crown burner).
WARNING!
Make sure the flame does not go
out when you quickly turn the knob
from the maximum position to the
minimum position.
7.5 Electrical connection
• The electrical work necessary to install
the appliance must be done by a quali-
fied electrician or competent person, ac-
cording to the current regulations.
• The appliance must be earthed.
• Always use a correctly installed shock-
proof socket.
• Make sure that there is access to the
mains plug after the installation.
• Do not pull the mains cable to discon-
nect the appliance. Always pull the
mains plug.
• The appliance must not be connected
with an extension cable, an adapter or a
multiple socket. There is a risk of fire.
Make sure that the ground connection
complies with the standards and regula-
tions force.
• The power cable must not touch any hot
parts.
• The electrical installation must have an
isolation device which lets you discon-
nect the appliance from the mains at all
poles. The isolation device must have a
contact opening width of minimum 3
mm.
• You must have the correct isolation devi-
ces: line protecting cut-outs, fuses
(screw type fuses removed from the
holder), earth leakage trips and contac-
tors.
• The connection cable parts must not be
heated to a temperature above 90°C.

Electrical Requirements

Permanent electrical installation must com-
ply with the latest I.E.E. Regulations and lo-
cal Electricity Board regulations. For your
own safety the installation must be done by
a qualified electrician (e.g. your local Elec-
tricity Board, or a contractor who is on the
roll of the National Inspection Council for
Electrical Installation Contracting [NICEIC]).
The manufacturer declines any liability
if these safety measures are not ob-
served.
The appliance must be connected to a 230
V 50 Hz AC electrical supply.
Before activating the appliance, make sure
the electrical supply voltage is the same as
that indicated on the rating plate. The rat-
ing plate is located on the bottom of the
appliance.
The appliance is supplied with a 3 core
flexible supply cord with a 3 amp plug. If it
is necessary to change the fuse, use a 3
amp ASTA-approved (BS 1362) fuse.
A
E
A)
Green and Yellow
B)
3 amp fuse
C)
Brown
D)
Cord clamp
E)
Blue
Should the plug need to be replaced for
any reason, the wires in the mains lead are
coloured in accordance with the following
code:
B
C
D