Parameter Switch Settings

12.3
12.3.1
Setting the Pump Number
This must be set at the pump, for each hose, so that communications with
a controller can take place. The location of this switch is shown in the
diagram below.
Depress the Parameter Switch nine (9) or more times until the message
'PnA XX' appears in the litres display window. When the switch is
pressed again 'Pnb XX ' will appear on the display. These two options
will toggle each time the switch is pressed. To alter either of the pump numbers, press and
hold the Parameter Switch when the pump number to be altered appears on the display. This
number will then increment. The switch should be released when the desired pump number is
displayed. The value of the displayed number will then be stored in the C4000 memory as the
pump number for that hose.
NOTE: For a single hose only 'Pn" will appear
12.3.2
Setting the Price
Using the Parameter Switch, follow the chart to set the price for the hose(s) in question.
Step
ACTION
1
Ensure that the nozzle is hung up
2
Press and Hold the Parameter switch until the
"Price per litre" is displayed.
3
Press and hold the Parameter switch.
4
When the digit is correct, release the Parameter
switch.
5
Repeat steps 3 and 4 for each digit of the 'Price per
litre'.
6
Press and release the Parameter switch 8 or more
times in quick succession
7
Repeat steps 3 to 5 above.
\\Cilaklfs1\shrdata\Masters\Installation Sheets\Master & Premier\MMR400-80S Installation
Sheet.doc
RESULT
Dispenser in idle state
The price for side 'A' is shown as 'PX.XXX' on the
litres display and 'PrA' is displayed on the money
display.
A digit, of the displayed 'Price per litre', will begin to
increment.
NOTE: the C4000 will reset itself if the Parameter
switch is left for more than 60 seconds.
Continue for Dual hose units
The price for side 'B' is shown as 'PX.XXX' on the
litres display and 'Prb' is displayed on the money
display.