Standard settings:
Display
Configuration
text
Option
r‐n
Rotate display
trI
Trickle speed
adjustment
bSt
Boost speed
adjustment
b15
Boost Overrun
time
h70
Humidity level
trigger
F‐0
Fan Control Mode F‐0 = CV disabled, wall /
c‐n
Comfort mode
unl
Enable / disable
lock code
‐‐‐
Menu lock code
cod
*If "0" is selected, the fan switches to Intermittent mode.
Advanced settings:
Display text
Configuration
Option
A‐Y
RH Ambient
Response
P‐Y
RH Rapid
Response
enable
Settings
Speed selection
Set trickle and boost speeds in l/s by using the
To convert m3/h to l/s, divide the m3/h by 3.6 (e.g. 54m3/h / 3.6 = 15 l/s).
The Trickle Speed cannot be higher than the Boost selection. Therefore it might be
necessary to modify the Boost selection before increasing the Trickle setting.
If "0" is selected for the trickle speed, the fan will be off until a boost signal is activated
(for example via LS/ pullcord/humidity).
Selections
r‐Y = display rotated
100mm: 0*, 5 to 30 l/s (Max limited by Boost Selection)
100mm: 6 to 35 l/s (Min limited by Trickle Selection)
b0 to b30 – 0 to 30 minutes (0 disables overrun)
h40 to h90 ‐ 40% to 90% relative humidity
window installation
c‐n = normal LS overrun
loc ‐ lock code enabled
Up / down selects current digit, X moves to next digit.
To change the lock code when "cod" is displayed select the up/down
buttons to select a digit then select X to move on to the next digit.
Selections
A‐Y Ambient Response
enabled
p‐Y = Rapid Response enabled
r‐n = display normal
F‐1 = CV disabled,
ducted installation
c‐Y = comfort mode
unl ‐ lock code disabled
(unlocked)
A‐n Ambient Response disabled
p‐n = Rapid Response disabled
and
buttons.
Default
15 l/s
F‐2 = CV Constant
Volume enabled
Default
Enabled
Y
r‐n
9l/s
15
70%
RH
F‐0
c‐n
unl
10c