AirTech ACR35CV-SELV Instrucciones de instalación y cableado - Página 8

Navegue en línea o descargue pdf Instrucciones de instalación y cableado para Ventilador AirTech ACR35CV-SELV. AirTech ACR35CV-SELV 12 páginas.

AirTech ACR35CV-SELV Instrucciones de instalación y cableado
Data Logger Menu
* When the display is rotated the decimal point will no longer display; eg. 055 represents
5.5KWh
Display text
tot run 00y 00d
Tri run 00y 00d
Boo run 00d
rhu run 00d
tot EnErgy 00.0
24h EnErgy 00
Cutting the power to the fan will not erase the stored data. To reset the data, hold
pullcord for 14 seconds while in the data logger menu.
In this example the display is showing a total run time of 1 year and 237 days.
In this example the display is showing 34Wh of energy consumption in the previous
Returning to commissioning mode
A further 5 second press of the Mode button will return the fan to the commissioning
menu.
SERVICING AND MAINTENANCE
WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST
BE ISOLATED FROM THE POWER SUPPLY DURING MAINTENANCE.
1. At intervals appropriate to the installation, the fan should be inspected and cleaned
to ensure there is no build-up of dirt or other deposits.
2. Carefully pull the front panel off the inner grille. (fig. 4)
3. Wipe the inlets and front face with a damp cloth until clean. Be careful not to push
dirt into the airflow sensor. (CV model only)
The fan has sealed for life bearings, which do not require lubrication.
Total run time in years and days
Trickle speed run time in years and days
Boosted run time in days
Humidity boosted run time in days
Total Energy used displayed in KWh*
Energy used in last 24 hours displayed in Wh
Data Examples
Text scrolling from right to left
Text scrolling from right to left
24h.
Description