Installation Mechanical

1.
Remove and discard plastic plugs from manifolds inlet/
outlet, and solenoids output.
2.
Install ¼" NPT nipples on solenoids outputs and install line
checks (Texsteam accessories TA4626 & TA0675)
3.
Forged steel plug rated for 3000psi is provided with the
unit. If manifold is located on opposite, remove, and install
on correct size.
4.
Connect ¼" fluid line to manifold inlet.
5.
Connect ¼" fluid output line to solenoid outputs.
NOTE: Solenoids are rated to 2500psi.
6.
A pressure relief valve is highly recommended to be install
at the manifold output, or in a pressure relief line to the
fluid inlet, or tank.
NOTE: A pressure relief valve accessory is available from Texsteam
(TA0173 & TA0180 Spring Kit). It can be connected.
7.
A bleed valve is recommended to be install on the drain
line before pressure relief valve with bleed outlet to a waste
reservoir. Bleed valve is available from Texsteam as an
accessory.
Multipoint Injection Controller
Model Number
Part #
TA 4626
TA 0675
TA 0173
TA 0180
TA 0179
Dimensions & Part List
Dimensions for Multipoint Controller are shown on the next
page. System shown is for 4 solenoids. Options for 2 solenoids
and 3 solenoids are also available.
Description
NIPPLE HEX 1/4 3000# 316 SS
LINE CHECK SS 1/4
Pressure Relief Valve 1/4 MNPT X 1/4
FNPT
Pressure Relief Valve - Spring Kit 2250-
3000PSI
Bleed Valve
Texsteam Pumps Multipoint Installation Manual 5