Electrolux 922718 Manual del usuario - Página 17

Navegue en línea o descargue pdf Manual del usuario para Campana de ventilación Electrolux 922718. Electrolux 922718 24 páginas. Built-in hood for electric oven
También para Electrolux 922718: Manual de instalación (32 páginas)

Electrolux 922718 Manual del usuario
F.2.4
TiO2 Filter replacement
The hood is equipped with a TiO2 catalytic filter. It is
located inside a central technical compartment,
behind the labyrinth filter, in front of the hood.
A pop-up window appears automatically on the oven
display when cleaning or replacement is required.
Its periodic replacement is recommended at the
same time as replacing the UV-C lamps.
1.
Remove the labyrinth filters, starting from the
middle one, raising and pulling the lower part
outwards (see F.2.1);
2.
Open the central technical compartment by
undoing the screws fixing the cover;
3.
Loosen the screws, move up the retaining plate;
4.
Remove four electrical connectors (pay attention
the right position for further refit)
5.
Remove the cassette that contain TiO2 Filter
and UVC lamps;
6.
Looser two rear screws and remove the cassette
that contain TiO2 Filter;
7.
Refit a new TiO2 Filter the relevant guides.
Make sure to refit them properly tightening the
rear screws;
8.
Fixing the cover right technical compartment by
the screws;
9.
Refit the labyrinth filters. Follow the operating
instructions in the chap F.2.1. Make sure to refit
them properly.
231007 OM_HO_04_ELUX_EN.docx -
17