MR1903D
Available IF Filters: 5, 10, and 15 MHz
IF Filter
UL Start
Bandwidth
Frequency
5 MHz
1850 MHz
5 MHz
1855 MHz
5 MHz
1860 MHz
5 MHz
1865 MHz
5 MHz
1870 MHz
5 MHz
1875 MHz
5 MHz
1880 MHz
5 MHz
1885 MHz
5 MHz
1890 MHz
5 MHz
1895 MHz
5 MHz
1900 MHz
5 MHz
1905 MHz
10 MHz
1850 MHz
10 MHz
1855 MHz
10 MHz
1860 MHz
10 MHz
1865 MHz
10 MHz
1870 MHz
10 MHz
1875 MHz
10 MHz
1880 MHz
10 MHz
1885 MHz
10 MHz
1890 MHz
10 MHz
1895 MHz
10 MHz
1900 MHz
15 MHz
1850 MHz
15 MHz
1870 MHz
15 MHz
1895 MHz
Andrew Wireless Systems GmbH * Industriering 10 * 86675 Buchdorf * Germany *
Page 6
UL Stop
DL Start
Frequency
Frequency
1855 MHz
1930 MHz
1860 MHz
1935 MHz
1865 MHz
1940 MHz
1870 MHz
1945 MHz
1875 MHz
1950 MHz
1880 MHz
1955 MHz
1885 MHz
1960 MHz
1890 MHz
1965 MHz
1895 MHz
1970 MHz
1900 MHz
1975 MHz
1905 MHz
1980 MHz
1910 MHz
1985 MHz
1860 MHz
1930 MHz
1865 MHz
1935 MHz
1870 MHz
1940 MHz
1875 MHz
1945 MHz
1880 MHz
1950 MHz
1885 MHz
1955 MHz
1890 MHz
1960 MHz
1895 MHz
1965 MHz
1900 MHz
1970 MHz
1905 MHz
1975 MHz
1910 MHz
1980 MHz
1865 MHz
1930 MHz
1885 MHz
1950 MHz
1910 MHz
1975 MHz
Standard frequency band setting MR1903D
Phone: +49 9099 69-0 * Fax: +49 9099 69-930 *
email: [email protected] * http://www.andrew.com
MR803D, MR853D, MR903D and MR1903D
DL Stop
PCS
Frequency
Block
1935 MHz
A1
1940 MHz
A2
1945 MHz
A3
1950 MHz
D
1955 MHz
B1
1960 MHz
B2
1965 MHz
B3
1970 MHz
E
1975 MHz
F
1980 MHz
C1
1985 MHz
C2
1990 MHz
C3
1940 MHz
A1 + A2
1945 MHz
A2+ A3
1950 MHz
A3 + D
1955 MHz
D+ B1
1960 MHz
B1 + B2
1965 MHz
B2+ B3
1970 MHz
B3 + E
1975 MHz
E+ F
1980 MHz
F + C1
1985 MHz
C1+ C2
1990 MHz
C2 + C3
1945 MHz
A
1965 MHz
B
1990 MHz
C
User's Guide for
SF 1
SF 2
Setting
Setting
0
8
1
C
3
0
4
4
5
8
6
C
8
0
9
4
A
8
B
C
D
0
E
4
0
8
1
C
3
0
4
4
5
8
6
C
8
0
9
4
A
8
B
C
D
0
0
8
5
8
B
C