Electrolux BETA EA 340 S1 BA Manual de servicio - Página 20
Navegue en línea o descargue pdf Manual de servicio para Campana de ventilación Electrolux BETA EA 340 S1 BA. Electrolux BETA EA 340 S1 BA 23 páginas.
6.2 Candle Lamp
Candle Lamp
Check right position of the lamps
Not working with power sourcing ON
Check with voltmeter on terminal
Lamps works?
NO
block feeder cable (230 V)
Change the feeder cable
NO
Value 230 V?
YES
Push light button on control assembly and
check with voltmeter on the lamp holder
(230 V)
Change the control assembly
NO
Value 230 V
YES
Change lamps
Lamp works
Final service
Q&CI - Technical Support
19
599 818 562 Rev. 00