Electrolux C260R Manual de funcionamiento e instalación - Página 9

Navegue en línea o descargue pdf Manual de funcionamiento e instalación para Campana de ventilación Electrolux C260R. Electrolux C260R 20 páginas. Hydro-extractor
También para Electrolux C260R: Manual de instrucciones (24 páginas), Manual de servicio (41 páginas)

Electrolux C260R Manual de funcionamiento e instalación
Installation of all types of hydro-extractor
Positioning
The extractor is to be placed as close to a floor
1
drain or gutter as possible.
The distance to the wall or other equipment must
be at least 250 mm. The distance on the left side
must be at least 250 mm.
To facilitate servicing, it is recommended to
leave a space of min. one metre behind the
machine.
Drain
Fit the rubber hose. Dimension of the drain pipe:
2
hose Ø76 mm.
Mount the hose so that there is an unrestricted
slope towards the floor gutter.
Leave at least 25 mm air space between the
drain hose and the floor grate or the gutter.
487 22 52 21 - Cent. 240, 260, 290, GB
Installation
1
2
9
1949
1950