Electrolux EFA90950 Manual del usuario - Página 16
Navegue en línea o descargue pdf Manual del usuario para Campana de ventilación Electrolux EFA90950. Electrolux EFA90950 28 páginas. Electrolux cooker hoods brochure
También para Electrolux EFA90950: Características (7 páginas)
16 electrolux
ELECTRICAL CONNECTIONS
DOUBLE INSULATED DO NOT EARTH
Electrical Requirements
EN
Any permanent electrical installation
must comply with the latest I.E.E.
Regulations and local Electricity Board
regulations. For your own safety this
should be undertaken by a qualifi ed
electrician e.g. your local Electricity
Board, or a contractor who is on the
roll of the National Inspection Council
for Electrical Installation Contracting
(NICEIC).
Electrical Connection
Before
connecting
supply ensure that the mains voltage
corresponds to the voltage on the rating
plate inside the cooker hood.
ELECTRICAL CONNECTIONS
to
the
This appliance is fi tted with a 2 core
mains cable and must be permanently
connected to the electricity supply
via
a
double-pole
3mm minimum contact gap on each
pole. A Switched Fuse Connection
Unit to BS1363 Part 4, fi tted with
a 3 Amp fuse, is a recommended
mains supply connection accessory
to ensure compliance with the Safety
Requirements applicable to fi xed wiring
instructions.
mains
This appliance conforms to BS 800:
1988 and EEC Directive No. 78 308
regarding suppression of ra dio and
television interference.
switch
having