7 Disposal
▪ Alternatively, when Emergency is set to:
▪ auto
SH
reduced/DHW
domestic hot water is still available.
▪ auto SH reduced/DHW off, space heating is reduced and
domestic hot water is NOT available.
▪ auto
SH
normal/DHW
normally but domestic hot water is NOT available.
Similarly as in Manual mode, the unit can take the full load with
the
backup
heater
if
the
Malfunctioning main menu screen.
When the heat pump fails,
interface.
Possible cause
Heat pump is damaged.
INFORMATION
When the backup heater takes over the heat load,
electricity consumption will be considerably higher.
6.5
Symptom: The system is making
gurgling noises after
commissioning
Possible cause
There is air in the system.
Various malfunctions.
(a)
We recommend to purge air with the air purge function
of the unit (to be performed by the installer). If you purge
air from the heat emitters or collectors, mind the
following:
WARNING
Air purging heat emitters or collectors. Before you
purge air from heat emitters or collectors, check if
is displayed on the home screen of the user interface.
▪ If not, you can purge air immediately.
▪ If yes, make sure that the room where you want to
purge air is sufficiently ventilated. Reason: Refrigerant
might leak into the water circuit, and subsequently into
the room when you purge air from the heat emitters or
collectors.
7
Disposal
NOTICE
Do NOT try to dismantle the system yourself: dismantling
of the system, treatment of the refrigerant, oil and other
parts MUST comply with applicable legislation. Units
MUST be treated at a specialised treatment facility for
reuse, recycling and recovery.
Operation manual
14
on, space heating is reduced but
off, space heating operates as
user
activates
this
via
or
will appear on the user
Corrective action
See
"6.1 To display the help text
malfunction" [ 4 13].
in case of a
Corrective action
(a)
Purge air from the system.
Check if
or
is displayed
on the home screen of the user
interface. See
"6.1 To display the
help text in case of a
malfunction" [ 4 13] for more
information about the
malfunction.
8
Glossary
DHW = Domestic hot water
Hot water used, in any type of building, for domestic
purposes.
LWT = Leaving water temperature
Water temperature at the water outlet of the heat pump.
the
or
EGSAH/X06+10(U)DA9W(G)
Daikin Altherma 3 GEO
4P569812-2B – 2019.10