Electrolux FHWC3060LSA Manual de uso y mantenimiento - Página 8

Navegue en línea o descargue pdf Manual de uso y mantenimiento para Campana de ventilación Electrolux FHWC3060LSA. Electrolux FHWC3060LSA 13 páginas. 30” and 36” range hood
También para Electrolux FHWC3060LSA: Manual de uso y mantenimiento (13 páginas)

Electrolux FHWC3060LSA Manual de uso y mantenimiento
8
Installing the hood
fig.
Desired range hood distance above a
36" high cook top
8 Feet
26"*
28-3/32"
3
27"*
29-3/32"
3
28"*
30-3/32"
3
29"*
31-3/32"
3
30"*
32-3/32"
3
31"*
33-3/32"
3
32"*
34-3/32"
3
33"
34"
35"
*
: with 10' extension chimney kit FHW10X60LS
1
(16) (not supplied). Please call Frigidaire at
1.800.944.9044 to order this kit.
*
: "
2
Dimension A
from cook top to where the bottom screw mounting
holes would be located.
*
: Recommended mounting height
3
Step 2:
• Install the range hood (1) either with wood screws
or long screws, depending on the wall type:
Wall type
Wood
Brick/Concrete
GB
Ceiling
0.9"
Long
9.8"
screws
9.3"
9.13"
9.8"
Wood
10"
screws
7.5"
Dimension
Wall
(see table)
Ceiling height
9 Feet
A*
A*
2
2
31-3/32"
32-3/32"
33-3/32"
34-3/32"
35-3/32"
36-3/32"
37-3/32"
" in the chart represents the height
Required screws
4 wood screws (14)
4 long screws (10)
• Insert 2 screws (10 or 14) in the top location, but
do not fully insert the screws (fig.
range hood (1) to the wall and tighten the screws.
Insert and tighten the 2 remaining screws on the
bottom location of the range hood (fig.
• Attach the collar (6) to the range hood (1). Secure
with 2 short screws (12) (fig.
fig.
A
fig.
fig.
NOTE
Sometimes, sponge tape covers the holes. If the
10 Feet *
1
holes are located behind the sponge tape, simply
A*
2
insert the screw through the sponge tape.
Step 3:
• Mount the glass cover (2) onto the range hood
30-3/32"
(1). Use the allen key (13) to secure with 4 sets of
31-3/32"
bolts, rubber washers, and washers (9) (fig.
32-3/32"
33-3/32"
fig.
34-3/32"
35-3/32"
36-3/32"
37-3/32"
Step 4:
• Mount upper and lower brackets (4, 5) on the
wall. Secure with the remaining 4 sets of long
screws (10). The notches of the lower bracket
should be facing up towards the ceiling (fig.
• Attach the exhaust duct (fig.
0.08"
). Mount the
/
).
).
fig.
0.08"
fig.
).
) .
) .