Atlantic Ultraviolet MIN-9 Manual del usuario - Página 12
Navegue en línea o descargue pdf Manual del usuario para Sistemas de filtración de agua Atlantic Ultraviolet MIN-9. Atlantic Ultraviolet MIN-9 20 páginas. Germicidal ultraviolet water purifiers
También para Atlantic Ultraviolet MIN-9: Manual del usuario (16 páginas), Manual del usuario (16 páginas)
R
O
ECOMMENDED
1.
Sentry™ Safety Sensor: Indicators provide constant visual monitoring of normal operation. In the event of ballast or lamp
failure the safety sensor indicates an alarm condition. The safety sensor is capable of operating an optional audio alarm and/
or solenoid valve.
2.
Audio Alarm: Activated by the Ultraviolet Monitor or Safety Sensor, alerts the user to any malfunction detected.
3.
Time Delay Mechanism: Provides a 2-minute warm up period during which the ultraviolet lamp achieves its full germicidal
output before the water is allowed to flow through the water purifier. The time delay mechanism is used in conjunction with,
and is electrically connected to the Solenoid Valve.
4.
Solenoid Valve: Operated in conjunction with the Ultraviolet Monitor, Safety Sensor or Time Delay Mechanism, this valve
prevents water flow through the water purifier when an abnormal condition is detected or in the event of power failure.
5.
Sure Flo™ Flow Control Valve: Limits water flow to the rated capacity of the purifier. The flow control valve is located
in line prior to the water purifier, and should be protected from ultraviolet exposure by the use of a 90-degree elbow fitting
between the flow control valve and the water purifier. Unless otherwise specified PVC flow control valves are supplied.
Stainless Steel Flow Control Valves are available for certain models. All PVC and Stainless Steel flow control valves are
male NPT. Consult Factory for other flow control valves
6.
Elapsed Time Indicator: A non-resettable display of the water purifier operating hours. Useful for scheduling and recording
maintenance and lamp replacement.
7.
Safety Goggles: Safety eyewear should be used as general-purpose safety protection and for additional shielding from
Ultraviolet rays
8.
Gloves: Gloves should be worn to offer hand protection from sharp threats like glass, wire, and metal.
NOTE: The recommended options above are available from Atlantic Ultraviolet Corporation or a distributor of Atlantic
Ultraviolet Corporation's products. For the other devices that may be required for your application, please contact your
local water treatment dealer, plumber or plumbing supplier.
MAINTENANCE
The water purifier is designed to operate with a minimal amount of maintenance, providing the water quality does not exceed
maximum concentration levels, see "Water Quality" in the "Product Application" section. Ordinary maintenance consists of;
•
Lamp replacement is recommended every 10,000 hours of operation, approximately 12 months of continuous service.
•
Cleaning of the quartz sleeve, when conditions warrant. It is recommended that the inspection of quartz sleeve be performed
after one month of use. If quartz sleeve is found to be coated (not clear), then frequency of cleaning must be done more often.
Deposits or discoloration on the surface of quartz sleeve are caused by excessive levels of the subject contaminant within
the water that is in contact with the quartz sleeve. Most often false deposits on the quartz sleeve are caused by an excess of
calcium (hardness), iron or manganese. Table 1 on Page 4 lists the maximum recommended concentration of these minerals
in the water that passes through the ultraviolet purifier. If you encounter difficulty due to deposits on the quartz sleeve, your
dealer will be able to recommend suitable pretreatment to reduce or eliminate the offending contaminant. If quartz sleeve is
clean (clear) then frequency of cleaning may be extended.
•
Always disconnect the water supply and completely drain the water purifier if it will be subjected to
temperatures below freezing.
•
Contact factory with questions.
I
NSPECTION
1.
Regularly inspect the water purifier to ensure that the germicidal lamp is still in operation.
•
An LED indicator light, located on the ballast, provides visual indication of germicidal lamp operation. This provides an
indication of lamp operation and does not indicate the level of ultraviolet intensity or transmission through the water.
•
Ballasts have a built-in audio alarm which will indicate lamp failure.
•
On purifiers so equipped, the Sentry
2. To ensure proper operation of the water purifier, regular biological testing should be performed on a schedule recommended
by local public health authorities, or at minimum; at installation, quarterly for the first year of service and annually, at lamp
replacement, for the life of the water purifier.
3.
Additional testing should be performed whenever modifications, change or additions are made to plumbing system, pumps,
well source water etc. to ensure adequate disinfection under new condition. (Continued on Page 13)
12
PTIONS
TM
Safety Sensor provides visual indication of ballast and ultraviolet lamp operation