Atlantic Ultraviolet S20 Manual del usuario - Página 6
Navegue en línea o descargue pdf Manual del usuario para Sistemas de filtración de agua Atlantic Ultraviolet S20. Atlantic Ultraviolet S20 20 páginas. High capacity systems
I
NSTALLATION
1. Remove water purifier from shipping carton. Inspect water purifier, power cord and plug for damage. Do not operate if
there is any damage to the purifier, power cord or plug.
separately. Keep the lamp aside for installation once the purifier has been properly installed.
2. Units occasionally experience damage in shipment due to the fragility of the quartz sleeve. It is, therefore, recommended
to inspect the water purifier for damage to the quartz sleeve after it has been removed from the shipping carton. Each end
of the unit as well as the inlet and outlet should be viewed to see if the quartz sleeve has experienced damage. If the
quartz sleeve shows signs of damage it should be replaced before the purifier is pressurized. See "Quartz Sleeve
Cleaning or Replacement" in the "Maintenance" section for the proper method of replacing the quartz sleeve in your
water purifier.
Note:
Solenoid plugs into the top of the Time Delay,
and the Time Delay into the Ultraviolet Monitor
COMMON
Incoming
PRE-TREATMENT or
Water
PUMPING DEVICES
Supply
1. Deionizer
2. Water Softener
3. Carbon Filters (GAC)
4. Pressure Tank
5. Pump
6. Reverse Osmosis
7. Prefilters
Ultraviolet Water Purifiers
should be installed closest
to the point of use. (POU)
3. The water purifier should be mounted horizontally on a flat dry surface. Secure the water purifier using the mounting
holes in the ballast housing or with the optional wall mounting kit. The purifier should not be solely supported by its
plumbing connections.
4. The water purifier must be connected to the cold water line only.
5. It is recommended that a 5-micron sediment filter be installed, in line, prior to the water purifier. The sediment filter will
stop or trap any particulates from entering the water purifier. Particulates may cause damage to the quartz sleeve, as well
as interfere with the purifier's ability to disinfect the water. The sediment filter may also help to reduce the amount of
routine cleaning of the quartz sleeve.
6. Shut off valves should be installed on both the inlet and outlet sides of the water purifier. The use of bypass valves is not
recommended. The shut off valves allow the purifier to be isolated from the water supply, which is required when
removing the quartz sleeve.
7. Unions should be installed on both the inlet and outlet of the water purifier; this will allow easy removal of the water
purifier from the plumbing, if required. Apply Teflon
8. When all plumbing connections are complete, allow water to enter the water purifier at a low flow rate, until the purifier
is pressurized. With the purifier pressurized, it should be checked for leaks. Once it is determined that there are no leaks,
the inlet valve can be fully opened.
9. Install lamp following the steps in "Lamp Installation or Replacement" section.
!
CAUTION: Lamp and quartz sleeve are easily damaged. Exercise care when installing lamp.
10. Once the plumbing hook ups are made, it is a good practice to disinfect the "downstream" plumbing between the purifier
and point of use. This is done by introducing chlorine into the purifier chamber, a 100-ppm of chlorine is suggested. With
the chlorine in the purifier chamber, turn the ultraviolet purifier on. Open the "downstream" outlet until a chlorine odor is
noticed. Close the outlet and allow the chlorine to remain in the plumbing for three (3) hours. Flush the plumbing with
ultraviolet purified water; allow the water to run for several minutes before use. This will allow the ultraviolet lamp to
reach its full germicidal output.
6
Figure 2 - Recommended Installation
Cold Water Line
5 Micron Filter
Valve
Union
12" Manual Wiper
50"
Recommended Minimum Clearance
For Lamp or Quartz Sleeve Removal
SANITRON
® Model S2400C is shipped with the lamp packed
(avoids ultraviolet degradation of exposed plastic pipe)
OPTIONAL EQUIPMENT
Two Minute Time Delay
Solenoid Valve
Flow Control Valve
Elbow
OPTIONAL EQUIPMENT
Ultraviolet Monitor
Audio Alarm
Wall Mounting Kit
OPTIONAL EQUIPMENT
®
tape to threads of inlet and outlet ports to ensure a tight seal.
Use of Metal Pipe is recommended for 12"
past elbow to the inlet or from the outlet.
POINT OF USE
(POU)
Elbow
Ultraviolet Water Purifiers
should be installed closest
to the point of use.
Outlet Line to
point of use
to be as short
as possible
Valve
Union
6" Minimum
Clearance for
Gland Access
Ultraviolet Water Purifier