Atlantic Ultraviolet Hygeaire LIND 24-EVO-2PM Manual del usuario - Página 7

Navegue en línea o descargue pdf Manual del usuario para Limpiador de aire Atlantic Ultraviolet Hygeaire LIND 24-EVO-2PM. Atlantic Ultraviolet Hygeaire LIND 24-EVO-2PM 12 páginas. Atlantic ultraviolet air disinfection owner's manual

I
LIND 24-EVO-2PM
NSTALLATION OF
1.
Installation and all wiring should confirm to state and local electrical codes as well as the current National
Electrical Code (NEC). Installation must be able to support approximately 32 pounds.
2.
After fixture is mounted and wired, open louver panels by removing thumbscrews. Install lamps (packed
separately), close panels and replace thumbscrews.
R
O
ECOMMENDED
PTIONS
TM
1.
Zenith
Ultraviolet Meter: Provides accurate Easy-To-Read Levels of Intensity that may be interpreted by
anyone, not just engineers. Zenith's
P
RECAUTIONS
Immediately following initial installation of the
TM
with the Zenith
Ultraviolet Meter, to insure that the ultraviolet radiant exposure of personnel is within acceptable
limits. Thereafter this procedure should be repeated whenever any maintenance is performed, including lamp changes
or whenever maintenance or repairs are performed in the vicinity of the fixture. In addition, procedures should be
adopted to insure that the fixture is switched off whenever personnel are working above the 6-foot level. Personnel who
work in and around the treated area should be briefed on the benefits and the precautions to be observed.
If there are any doubts or questions about the safety or the effectiveness of the installation, or if a sensitive ultraviolet
meter is required, please contact the Factory.
Figure 2 - LIND 24-EVO-2PM Installation
TM
design makes it insensitive to ambient lighting within the area being surveyed.
®
Hygeaire
fixture, the occupied area, of the room, should be surveyed
7