Advanced Poly-Packaging T-375 Instrucciones
Navegue en línea o descargue pdf Instrucciones para Equipos de envasado Advanced Poly-Packaging T-375. Advanced Poly-Packaging T-375 3 páginas. Calibrate thermocouple
Document: #HT000129
Document Title: Calibrate Thermocouple
Product(s): T-375
Procedure:
To calibrate a thermocouple after replacement or repair, it is necessary to have
exterior temperature sensor (Fluke Thermocouple Thermometer 51/52 Series II or
equivalent) in order to compare and adjust the temperature readings.
Set the thermometer to the same scale as the Bagger (°F or °C).
Place the temperature sensor probe from the Fluke or equivalent thermometer in
contact with the Heater Bar as close to the point of contact for the Thermocouple
Wire as possible.
Access the Temperature Calibration Screen, by starting at the Main Menu,
proceeding to the Technical Assistance and Bagger Factory Screens.
Press "Temperature Calibration" button on right side of Bagger Factory Settings
screen.