Assembly
1
Mounting the
Insert the armature (4) together with the
armature
field (5) into the housing.
2
Only applicable for PN 2000 SMF2:
nsert the complete switch (6), with the
torque pre-setting dial and the torque
switch into the housing. Insert the cords
into the provided reliefs and connect them
according to the wiring diagram.
3
Mount the switch.
4
Insert the brush holder insulations (1) and
the brush holders (3) together with the
carbon brushes (2) into the housing.
1
Assembling the
Fit the housing (3) and fasten it with
housing
screws. Take care that no cables are
squeezed or jammed.
2
Fix the power supply lead with the connec-
tors (4) and fasten the cable clip (5) with
screws.
3
Screw down (1) the service cover (2).
Repair Instructions No.176.11/95
PN 2000-2/ MF/ MF2/ N/ SMF2/ spec.N
1
3
2
1
1
2
3
2
4
4
5
PAGE
5
4
1
5
6
2
3