Atlas Copco PHE 6 S Instrucciones de reparación - Página 3
Navegue en línea o descargue pdf Instrucciones de reparación para Taladro Atlas Copco PHE 6 S. Atlas Copco PHE 6 S 18 páginas.
1
Detaching the
Loosen the screws (1) and remove the
carbon brushes
brush covers (2).
2
Lift the brush springs (5) off the respective
carbon brushes (3) and place them on the
upper edge of the brush holders (4).
3
Pull both cable lugs (h and i) off the carbon
brushes (3) and remove them.
1
Dismantling the
Loosen the two screws (G) of the hous-
handgrip
ing (F).
2
Remove the handle screw (E) by steady-
ing the knurled nut (5) at the same time.
Remove the knurled nut (5).
3
Loosen the screw (B) and lever off the
handle cover (A) from below (it is not pos-
sible to lever off the handle cover from
above without destroying it!).
4
Unscrew the four screws (6) from the right
half of the handle (7).
5
Unscrew both Torx screws (8) TX 30 of
the handgrip holder (4) and remove them.
6
Pull off the handle shells completely with
the housing (F).
7
Remove the damping element (2).
8
Disconnect the plug-in connection (1) be-
tween the motor and the pair of handle
shells.
9
Remove the handgrip holder (4) and the
rubber collar (3) from the handle shells.
10
Remove the left handle shell (C) with the
holding-down device.
11
Loosen the cable clamps (D) and lay bare
the connecting cable (H) with the cable
entry sleeve.
12
Remove the switch (9) with the capacitor
from the handle shell.
Attention: Do under no circumstances
further dismantle the damping ele-
ment!
Repair Instructions No.181.03/98
h
3
2
1
7
6
5
4
3
e
2
1
PHE 6 H / PHE 6 S
4
i
A
B
8
9
b
e
a
D
a
b
H
j
k
G
PAGE
2
5
3
C
4
E
F