Bose FreeSpace 6 Manual del instalador - Página 9
Navegue en línea o descargue pdf Manual del instalador para Sistema de altavoces Bose FreeSpace 6. Bose FreeSpace 6 39 páginas. Business music system
También para Bose FreeSpace 6: Manual del instalador (16 páginas), Especificaciones técnicas (2 páginas)
2 inch
(50.8 mm)
all sides
2 inch
(50.8 mm)
all sides
The front edge should be no more than 1 inch (25.4 mm) from the opening. Leave the opening uncovered.
Note: Do not place anything in the space that blocks the ventilation slots or adds heat.
1.2 Remote control
The remote control should be wall mounted in an electrical box (not included) similar to a light-switch electrical box.
Install the control where day-to-day adjustments will be easy to make.
1.3 Loudspeakers
The loudspeakers can be mounted to most fixed or suspended ceilings or walls strong enough to support the
combined weight of the hardware and loudspeakers. Bose
mounted in unsuitable places.
Permanent ceilings (gypsum board or plaster) may conceal electrical conduits or other hazards. Check for these
hazards before cutting mounting holes, especially if using power equipment.
These loudspeakers are UL listed as vandal resistant and will resist malicious damage from a sharp object.
However, they can be removed, or damaged with blows from a heavy object. If vandalism is a concern,
consider mounting the loudspeakers out of reach.
1.3.1 Clearance
Allow enough clearance for both the depth of the ceiling loudspeaker and the wire from the electrical fitting. To
decrease this distance, an angled electrical fitting may have to be used if flexible metallic conduit or flexible metallic
tubing is used.
®
will not be responsible for brackets or loudspeakers
AM180090_02_V.pdf • May 7, 2002
1.0 System Placement
1 inch
(25.4 mm)
1 inch
(25.4 mm)
9