ELECTRICAL SHOCK HAZARD
•
•
To keep your unit operating at peak efficiency, ensure that
the cooling pads are kept clean and dust-free. Dust and
other particles have an adverse effect on the media's
ability to introduce water into the air stream. If the pad
surface becomes dirty or dusty, clean with a soft brush
and water.
Daily maintenance:
At start-up: It is best to run the pump several minutes
before the fan is started to clean out any debris on the
media.
At shut-down: When shutting down your evaporative
cooler at the end of each workday, the pump should be
turned off approximately 15 minutes before the fan is
turned off. This will allow the pads to drain and dry out.
This simple guideline will ensure long and efficient pad life
as well as help to control mildew and bacteria growth.
Periodic maintenance:
Depending on how often the unit operates, this procedure
should be performed anywhere from every week for
heavy use to monthly for light use.
1. Drain reservoir.
2. Remove cooling pads.
3. Clean out reservoir with either a towel or wet/dry
vacuum.
4. Reinstall pads and pad retainers.
Annual shutdown / Storage:
1. Wash down the media to flush out all the debris.
2. Open the drain in the sump to drain out any
standing water.
3. Wash the interior of the unit to remove any
algae or micro-organisms as well as calcium
deposits. A weak dilution of muriatic acid will
help clean the alkali (calcium) deposits.
Commercial chlorine will kill and clean out the
algae.
4. Store the unit in a dry area and cover if possible
to prevent dust build-up.
Page 12 of 16
Serious injury or death may
occur.
Disconnect from electrical
supply before servicing this
product.
Removing the cooling media:
In order to perform any maintenance on internal
components the cooling pads must be removed to
access the inside of the unit.
Media removal / replacement is simple, if you follow
these instructions! The media is soft when wet so be
very careful when handling.
separate flute angles, which are transverse to each
other and alternate across the face of the media.
One flute is 45° and the other is 15°. The alignment
of the flute arrangement in relation to the direction of
airflow is critically important. The 45° flute must be
aligned upwards in the direction of the airflow. The
15° flute must be aligned downwards in the direction
of the airflow.
1. Using a 5/16" nut driver, remove the (2)
screws holding the pad retainer bracket in
place. Save all hardware.
2. The pad may be tilted out of the unit and
lifted out of the drain tray.
Note: Reinstall pads correctly; refer to sides of
pad material for airflow direction.
Screws
Pad retainer
Pad material
CHEMICAL BURN HAZARD
POISONOUS GAS HAZARD
Serious injury or death may
•
occur.
Read, understand and follow
•
all chemical manufacturers'
instructions when using the
chemicals noted in these
pages.
The media has two
Airflow
Direction