Advanced Radio Air Safe Manual del usuario - Página 8
Navegue en línea o descargue pdf Manual del usuario para Equipos de grabación Advanced Radio Air Safe. Advanced Radio Air Safe 12 páginas. Failsafe gear sequencer
Sequencer Outputs 1-6 Programming
Highlight and select any of the 6 SEQ OUTPUTS to take
you to the individual output programming screen.
For our example we will use OUTPUT 1.
Note: All outputs have the same features.
Sequencer Output Programming Screen
SEQ OUTPUT 1 at the top of the screen shows the cur-
rently selected output. Any changes made to values will
be made to the shown output. In this case Output 1.
Joystick → RIGHT Arrow — Increases a value.
Joystick ← LEFT Arrow — Decreases a value.
Hint: Press and hold the joystick left or right to move the value/position quicker.
SPEED— Highlight this menu item to slow servo speed. Higher values slow the speed. Lower
values increase the speed. A value of zero is servo full speed. Factory default is 1.0
UP POS—Highlight this menu item to alter the UP POSITION of an air valve or servo con-
trolled door.
DN POS—Highlight this menu item to alter the DOWN POSITION of an air valve or servo
controlled door.
NOTE: It is important to have the air valve/servo position correctly set before you pro-
gram the sequencer. The sequencer assumes the Up and Down positions have been cor-
rectly set.
Screens and Usage
RETURN
SEQ OUTPUT 1
SEQ OUTPUT 2
SEQ OUTPUT 3
SEQ OUTPUT 4
SEQ OUTPUT 5
SEQ OUTPUT 6
RETURN
SEQ OUTPUT 1
SPEED
1.0
UP POS
2000uS
DN POS
1000uS