Bose FreeSpace E-4 Manual del usuario - Página 6
Navegue en línea o descargue pdf Manual del usuario para Sistema estéreo Bose FreeSpace E-4. Bose FreeSpace E-4 15 páginas. Business music system
También para Bose FreeSpace E-4: Manual del usuario (18 páginas), Manual de inicio rápido (4 páginas), Manual del usuario (14 páginas), Manual del usuario (19 páginas)
4.1 Introduction
This section provides instructions for installing the FreeSpace
E-4 system hardware on a tabletop or in a rack.
4.2 Included accessories
The following accessories are shipped with the E-4 unit in the
FreeSpace E-4 System Accessory Kit (PC030105).
• 2-terminal input connectors (6) – For wiring
Auto Volume mics to the
SENSE MICROPHONES jacks
• 3-terminal input connectors (2) – For wiring
equipment to the AUX MIC/LINE 3 jacks
• 4-terminal input connectors (3) – For wiring
equipment to the ZONE 4 LINE OUT,
PAGE/MIC/LINE 4, and
DIRECT IN/CONTROL jacks
• 2-terminal output connectors (5) – For wir-
ing speaker cables to the ZONE OUT jacks
• Rubber feet (4) – For installing the E-4 unit
on a level surface
• Replacement voltage label (2) – Used on
the OUTPUT VOLTAGE selection switch
• FreeSpace system Installer™
software CD – Contains application
software for programming the E-4
system
4.0 Hardware Installation
®
25 of 76
4.3 Placement guidelines
• Place the E-4 unit where it is protected from heat and allowed
adequate ventilation.
• Place the E-4 unit away from direct heat sources, such as heat-
ing vents and radiators.
• Make sure that air can circulate freely behind, beside, and
above the unit. Allow six inches on all sides.
Installer's Note: Do not allow the chassis to exceed the
maximum operating temperature of 50˚ C (122˚ F). Be aware
of conditions in an enclosed rack that may increase the tem-
perature above room-ambient conditions.
4.4 Shelf mounting the E-4 unit
The E-4 unit is ideal for shelf mounting. The included accessory
kit contains four rubber feet for the bottom of the E-4 chassis.
The rubber feet will protect the surface on which the E-4 unit is
installed and help prevent movement of the E-4 unit. Be sure to
follow the "Placement Guidelines" previously described when
choosing a location for the E-4 unit.